The Description Module contains narrative descriptions of the clinical trial, including a brief summary and detailed description. These descriptions provide important information about the study's purpose, methodology, and key details in language accessible to both researchers and the general public.

Description Module path is as follows:

Study -> Protocol Section -> Description Module

Description Module


Ignite Creation Date: 2025-12-25 @ 2:37 AM
Ignite Modification Date: 2025-12-25 @ 2:37 AM
NCT ID: NCT07163234
Brief Summary: This is a first-in-human, prospective, single-arm, phase I clinical study evaluating the safety of the iPerf femoral arterial cannula in patients undergoing planned cardiac surgery requiring extracorporeal circulation (ECC) via a femoral approach for up to 6 hours. The iPerf device is a dual-lumen arterial cannula designed to provide systemic and lower limb perfusion during ECC, with the goal of reducing the risk of acute limb ischemia. The study will be conducted at a single center in France and will include 15 adult patients. Primary outcomes focus on procedure-related and late adverse events up to 30 days post-surgery. Secondary objectives include assessment of ischemic events, tissue oxygen saturation, and surgeon satisfaction with device handling. The study aims to demonstrate feasibility and safety of the iPerf cannula as an innovative solution for lower limb perfusion during femoral artery cannulation.
Detailed Description: This is a first-in-human, prospective, single-arm, phase I clinical study evaluating the safety of the iPerf femoral arterial cannula in patients undergoing planned cardiac surgery requiring extracorporeal circulation (ECC) via a femoral approach for up to 6 hours. The iPerf device is a dual-lumen arterial cannula designed to provide systemic and lower limb perfusion during ECC, with the goal of reducing the risk of acute limb ischemia. The study will be conducted at a single center in France and will include 15 adult patients. Primary outcomes focus on procedure-related and late adverse events up to 30 days post-surgery. Secondary objectives include assessment of ischemic events, tissue oxygen saturation, and surgeon satisfaction with device handling. The study aims to demonstrate feasibility and safety of the iPerf cannula as an innovative solution for lower limb perfusion during femoral artery cannulation.
Study: NCT07163234
Study Brief:
Protocol Section: NCT07163234