Description Module

Description Module

The Description Module contains narrative descriptions of the clinical trial, including a brief summary and detailed description. These descriptions provide important information about the study's purpose, methodology, and key details in language accessible to both researchers and the general public.

Description Module path is as follows:

Study -> Protocol Section -> Description Module

Description Module


Ignite Creation Date: 2025-12-25 @ 2:46 AM
Ignite Modification Date: 2025-12-25 @ 2:46 AM
NCT ID: NCT02682433
Brief Summary: Uterine cavity diseases can cause mild to severe symptoms, and may indicate the functional problems of the female reproductive system. Many articles examine the efficacy of diagnostic hysteroscopy compared to sonohysterography in the diagnosis of uterine cavity diseases. Most of the articles are from the last decade, but the subject has been laid aside in the recent years. Antonio Simone Lagana and his group have found that there is 100% correlation in uterine cavity structure between diagnostic hysteroscopy and sonohysterography, and only 78% correlation when it comes to intrauterine fibroids and polyps. Walid El-Sherbiny, MD and his group have found that there is a significant advantage to three-dimensional sonohysterography over two-dimensional in the diagnosis of uterine cavity diseases. No significant difference was observed, and 97% correlation was found, comparing three-dimensional sonar and hysteroscopy. Work rationale is that there is a reason to reconsider the status of the diagnostic hysteroscopy to sonohysterography due to evolving technologies, and an improvement in resolution and three dimensional technologies.
Detailed Description: Uterine cavity diseases can cause mild to severe symptoms, and may indicate the functional problems of the female reproductive system. Many articles examine the efficacy of diagnostic hysteroscopy compared to sonohysterography in the diagnosis of uterine cavity diseases. Most of the articles are from the last decade, but the subject has been laid aside in the recent years. Antonio Simone Lagana and his group have found that there is 100% correlation in uterine cavity structure between diagnostic hysteroscopy and sonohysterography, and only 78% correlation when it comes to intrauterine fibroids and polyps. Walid El-Sherbiny, MD and his group have found that there is a significant advantage to three-dimensional sonohysterography over two-dimensional in the diagnosis of uterine cavity diseases. No significant difference was observed, and 97% correlation was found, comparing three-dimensional sonar and hysteroscopy. Work rationale is that there is a reason to reconsider the status of the diagnostic hysteroscopy to sonohysterography due to evolving technologies, and an improvement in resolution and three dimensional technologies. Purpose of the study: Comparison of the sensitivity, specificity, and the amount of information between diagnostic hysteroscopy and sonohysterography (Two and three-dimensional, in abdominal and vaginal access). The comparison will be will be made immediately after the completion of diagnostic hysteroscopy test, while using liquid drizzled earlier during the hysteroscopy, in order to simulate sonohysterography which is considered less intrusive and is made As part of standard treatment.
Study: NCT02682433
Study Brief:
Protocol Section: NCT02682433