The Description Module contains narrative descriptions of the clinical trial, including a brief summary and detailed description. These descriptions provide important information about the study's purpose, methodology, and key details in language accessible to both researchers and the general public.

Description Module path is as follows:

Study -> Protocol Section -> Description Module

Description Module


Ignite Creation Date: 2025-12-25 @ 4:18 AM
Ignite Modification Date: 2025-12-25 @ 4:18 AM
NCT ID: NCT03634020
Brief Summary: To confirm the safety and performance of the DynamX Sirolimus-eluting Coronary Bioadaptor System (SECBS) in de novo native coronary artery lesions using clinical and imaging endpoints. Clinical follow-up will be conducted in all patients at 30 days, 6 and 12 months. Imaging follow-up will be conducted at 6 months.
Detailed Description: The DynamX Sirolimus Study is a prospective, consecutive enrollment, single-arm study designed to enroll up to 30 patients requiring treatment of up to two de novo lesions ≤ 24 mm in length in vessels ≥ 2.5 mm and ≤ 3.5 mm in diameter. One or two designated target lesions, located in separate epicardial vessels (RCA, LCX or LAD), and meeting the inclusion/exclusion criteria may be treated with the DynamX SECBS. Alternatively, one target lesion may be treated with the DynamX SECBS after successful, uncomplicated treatment of a non-target lesion, located in a separate epicardial vessel, with any commercially-available DES. Acceptable example: non-target RCA lesion and LAD target lesion. Not acceptable example: LAD non-target lesion and 1st diagonal target lesion. The primary safety endpoint is Target Lesion Failure at 6 months. TLF is a composite endpoint defined as cardiac death, target vessel MI, and clinically-indicated target lesion revascularization The primary efficacy endpoint is late lumen loss at 6 months, assessed by angiography Additional secondary safety and effectiveness endpoints will be evaluated at 30 days, 6 and 12 months Using visual assessment, the target lesion must measure ≥ 2.5 mm and ≤ 3.5 mm in diameter and ≤ 24 mm in length able to be covered by a single DynamX Sirolimus Bioadaptor including 2 mm of healthy vessel on either side of the planned treatment area. The patient will be eligible for stent (also called bioadaptor) implantation only after satisfactory lesion pre-dilatation defined as: ≥ TIMI 2 flow, and no dissection greater than Grade B (NHLBI) able to be covered with a single DynamX SECBS
Study: NCT03634020
Study Brief:
Protocol Section: NCT03634020