Description Module

Description Module

The Description Module contains narrative descriptions of the clinical trial, including a brief summary and detailed description. These descriptions provide important information about the study's purpose, methodology, and key details in language accessible to both researchers and the general public.

Description Module path is as follows:

Study -> Protocol Section -> Description Module

Description Module


Ignite Creation Date: 2025-12-24 @ 5:57 PM
Ignite Modification Date: 2025-12-24 @ 5:57 PM
NCT ID: NCT06224868
Brief Summary: Laparoscopic surgeries are now more popular because of the advantages such as shorter hospital stay, minimal scar. In order to perform laparoscopic surgery, pneumoperitoneum should be initiated. The optic nerve sheath is an extension of the dura mater and the subarachnoid space is continuous with the intracranial subarachnoid space. Therefore, non-invasive monitoring of the increase in intracranial pressure (ICP) can be achieved by measuring the optic nerve and sheath diameter with ultrasound. Since ONSD measurement with ultrasound is an easily applicable technique, it is useful in monitoring intracranial pressure changes based on the optic nerve diameter during intraoperative changes
Detailed Description: Laparoscopic surgeries are now becoming increasingly common compared to traditional laparotomies, as they have advantages such as more minimal scarring, shorter hospital stay, fewer complications, and early mobilization. In these surgeries, pneumoperitoneum provided with carbon dioxide (CO2) has many effects on the cardiovascular, pulmonary, renal, metabolic and cerebral systems. Pulmonary compliance and functional residual capacity decrease due to pnemoperitoneum, ventilation/perfusion mismatch occurs, and as a result, hypoxemia may occur. A minimum of 4-6 cm H20 positive end-expiratory pressure (PEEP) should be applied to all intubated patients under general anesthesia to reduce postoperative pulmonary complications (especially atelectasis) and prevent ventilation/perfusion mismatch and hypoxemia. The optic nerve sheath is an extension of the dura mater and the subarachnoid space is continuous with the intracranial subarachnoid space. Therefore, non-invasive monitoring of the increase in intracranial pressure (ICP) can be achieved by measuring the optic nerve and sheath diameter with ultrasound. When ICP is \> 20 mm Hg, measuring the optic nerve sheath diameter (ONSD) between 5.2 and 5.9 mm has a sensitivity of 74-95% and a specificity of 74-100%. Since ONSD measurement with ultrasound is an easily applicable technique, it is useful in monitoring intracranial pressure changes based on the optic nerve diameter during intraoperative changes (trendelenburg/reverse trendelenburg position, pneumoperitoneum , PEEP in mechanical ventilation).
Study: NCT06224868
Study Brief:
Protocol Section: NCT06224868