The Description Module contains narrative descriptions of the clinical trial, including a brief summary and detailed description. These descriptions provide important information about the study's purpose, methodology, and key details in language accessible to both researchers and the general public.

Description Module path is as follows:

Study -> Protocol Section -> Description Module

Description Module


Ignite Creation Date: 2025-12-24 @ 6:35 PM
Ignite Modification Date: 2025-12-24 @ 6:35 PM
NCT ID: NCT03932357
Brief Summary: accuracy of CBCT in measuring soft tissue thickness by using a radiopaque material as the real finding and measurements on pig jaws
Detailed Description: * Pig jaws will be included in this study. * Soft tissue surfaces were lightly covered with barium sulfate powder using a powder spray. CBCT was taken. * A periodontal probe and a rubber stop were used for the measurement of trans-gingival probing thickness (TPT). * After that, flap were elevated, and actual thickness of soft-tissue (actual thickness, AT) was measured. The Analytical phase: * In order to assess soft tissue thickness and bone levels an electronic digital caliper (Shenhan Measuring Tools Co., LTD, Shanghai) will used for measuring the transgingival probing thickness on the pig jaws. * A graduated Naber's probe will be used for measuring the transgingival probing thickness. Soft tissue thickness measurements: * Intra-observer variability was tested under the supervision of the director. * For the measurement of radiographic thickness (RT), wet soft tissue surfaces were covered with barium sulfate powder (SoloTop; Taejoon, Seoul, Korea), a radiopaque material used as a contrast medium. * A probes and rubber stop were used for the measurement of transgingival probing thickness (TPT). * A rubber stop was placed in contact with the surface to facilitate the measurement of tissue thickness, and then TPT was measured with digital calipers. All measurements were rounded to the nearest 0.01 mm. * For the measurement of actual thickness (AT), an incision was made onto each marked area. After flap elevation, actual soft tissue thickness was measured using the same method that was used for TPT. Radiographic examination * The pig jaws will then be imaged with CBCT. * CBCT scanning will be performed using a PROMAX R 3DMid CBCT device (Planmeca Oy, Helsinki, Finland) with scanning protocol 90 kVp, 8 mA and 13.58 seconds exposure time with a single 360 degree rotation ROMEXIS software. The jawes will be placed on the horizontal plate of the device. The midline and mandibular position will be adjusted using the laser guide
Study: NCT03932357
Study Brief:
Protocol Section: NCT03932357