The Description Module contains narrative descriptions of the clinical trial, including a brief summary and detailed description. These descriptions provide important information about the study's purpose, methodology, and key details in language accessible to both researchers and the general public.

Description Module path is as follows:

Study -> Protocol Section -> Description Module

Description Module


Ignite Creation Date: 2025-12-24 @ 7:09 PM
Ignite Modification Date: 2025-12-24 @ 7:09 PM
NCT ID: NCT00459303
Brief Summary: This study is to compare intraindividually the functional vision provided by two different posterior chamber intraocular lenses: AMO Tecnis Z9000 and Alcon SA60AT Acrysoft. To see if the aspherical intraocular lenses provide better functional vision than traditional spherical intraocular lenses.
Detailed Description: In this prospective study, 20 patients with bilateral catarct presenting for cataract surgery are randomly assigned to recieve an aspherical intraocular lens(AMO Tecnis Z9000) in one eye and a spherical intraocular lens(Alcon SA60AT Acrysof)in the other. All surgeries are performed by one experienced surgeon(Fung-Rong Hu,MD)with clear cornea small incision phacoemulsification and in-the-bag posterior chamber intraocular implantation. The patients are followed for 3 months, and postoperative contrast sensitivity, contrast acuity, corneal \& total ocular high-ordered aberrations are measured and compared intraidividually between two different IOL groups. Outcome Measurement: 1. Contrast sensitivity testing: measured with spectacle correction for the target distance of three meters using wall-mounted FACT sine-wave grating chart with nine levels of contrast.The graphic contrast sensitivity is recorded as a log functional units on the y-axis and displayed for five spatial frequency targets (1.5, 3, 6, 12, 18 cycles per degree (cpd))on x- axis. 2. Contrast acuity testing: measured with spectacle correction for the target distance of three meters using logMAR letter chart(Precision VisionĀ®)represented on a wall-mounted illuminator cabinet.Two types of contrast charts are used, high contrast(Cat.No.2103 SLOAN translucent chart)and low contrast(Cat.No.2132 10% SLOAN translucent chart),and are tested under both photopic and mesopic conditions. 3. Pupil diameters: measured by Colvard infrared pupillometer (Oasis. Medical, Glendora, CA, USA )under both photopic and mesopic luminance levels. 4. Corneal aberration analysis: performed with TMS-4 (Tomey, Japan).The corneal HOAs are described with Zernike polynomials of 3rd-to 5th- order root-mean-square(RMS)of central 6mm diameter using VOLPro 6.89 software(Fa. Sarver and Associates, Carbondale. Ill, USA). 5. Total ocular aberration analysis: performed with a Hartmann-Shack aberrometer(Zywave, Bausch \& Lomb Inc., Rochester, New. York)under maximal mydriasis with Mydrin-P(phenylephrine hydrochloride 0.5% and tropicamide 0.5%, Santen).The wavefront errors were described using Zernike polynomials RMS for total HOA at pupil diameter of 5 mm and 6 mm, primary spherical (Z 4,0) and 3rd-to 5th-order aberration at pupil diameter of 6 mm. Data Analysis: * Mann-Whitney U matched-paired test was used with STATA software * P values of 0.05 or less were considered statistically significant
Study: NCT00459303
Study Brief:
Protocol Section: NCT00459303