The Description Module contains narrative descriptions of the clinical trial, including a brief summary and detailed description. These descriptions provide important information about the study's purpose, methodology, and key details in language accessible to both researchers and the general public.

Description Module path is as follows:

Study -> Protocol Section -> Description Module

Description Module


Ignite Creation Date: 2025-12-24 @ 11:33 PM
Ignite Modification Date: 2025-12-24 @ 11:33 PM
NCT ID: NCT01788956
Brief Summary: The intent of this study is to validate the venous blood oxygenation measurements of the Mespere VA Oximeter compared to the saturations measured by venous blood sampling through an inserted central vein catheter, which is currently the standard of care for measuring SvO2
Detailed Description: The conventional bedside pulse oximeter has been a standard in clinical care for non-invasive hemodynamic monitoring and measures arterial blood oxygenation. To date, a non-invasive bedside monitor for measuring mixed venous oxygen saturation (SvO2) has not been developed. The clinical applications of venous oximetry are numerous and include management of severe sepsis and septic shock, trauma and hemorrhagic shock, heart failure and cardiac arrest. The existing method for venous blood oxygenation monitored is either through an invasive fiber optic catheter, or intermittently by blood sampling through a central venous catheter Oximetry. However, SvO2 measurements using fiber optic catheters are very expensive, and all central line insertions include inherent risks. Also, insertion of a central line is in some circumstances not feasible (e.g. discomfort/limited experience in central line insertion, unavailability of specific monitoring systems etc.) resulting in inappropriate therapy usually guided by SvO2. Therefore, a non-invasive monitor to measure SvO2 at the bedside negating the requirement for a central line insertion would be of clinical benefit and allow appropriate therapy of many patients listed above at a time when therapy has the most benefit. The Mespere VA Oximeter is a non-invasive medical device for monitoring of venous blood oxygenation. Continuous measurement of venous oxygenation will be beneficial because it will help the physician better understand local ischemia as well as provide better guidance for the physician to be able to best treat the patient and decrease their burden of illness.
Study: NCT01788956
Study Brief:
Protocol Section: NCT01788956