Description Module

Description Module

The Description Module contains narrative descriptions of the clinical trial, including a brief summary and detailed description. These descriptions provide important information about the study's purpose, methodology, and key details in language accessible to both researchers and the general public.

Description Module path is as follows:

Study -> Protocol Section -> Description Module

Description Module


Ignite Creation Date: 2025-12-25 @ 12:00 AM
Ignite Modification Date: 2025-12-25 @ 12:00 AM
NCT ID: NCT00220558
Brief Summary: The objective of this study is to compare the Cypher Select-TM Sirolimus Eluting Stent (SES) with the SONIC-TM Bare Metal Stent (BMS) in the treatment of Chronic Total Occlusion lesions (CTO). The primary hypothesis is that, at 8-month follow-up, the minimal luminal diameter (MLD) of the coronary segment treated with stent implantation in CTO lesions is significantly larger with the use of SES compared to BMS. The treated segment is defined as the segment covered by the stent(s) plus 5 mm proximally and distally to the stent(s).
Detailed Description: This is a multicenter, prospective, randomized study that will be conducted at up to 22 centers in Italy. All patients who meet the eligibility criteria will be randomized to Cypher Select-TM Stent or SONIC-TM Stent. Patients will have repeat angiography at 8 months and clinical follow-up to 2 years. The study population will consist of 150 patients with single chronic total occlusion in a native coronary artery with a reference diameter between 2.75 mm and 3.75 mm. The occlusion has to be dilatable by balloon angioplasty and can be fully covered by \< 2 stents of ≤33 mm of length each. The CTO is defined as obstruction of a native coronary artery, at least 30 days old, with no luminal continuity and with Thrombolysis in Myocardial Infarction (TIMI) flow grade 0 or 1. Following confirmation of eligibility criteria and successful pre-dilating of the CTO, patients will be randomized in a 1:1 ratio to receive SES CYPHER SELECT Stent or BMS SONIC Stent. The coronary angiograms will be assessed at a core laboratory with Quantitative Coronary Angiography. Quantitative angiographic parameters including minimal luminal diameter, binary restenosis rate, total reocclusion rate, late luminal loss, will be evaluated at 8 months. The incidence of clinical events, including death, myocardial infarction, target vessel revascularization, stent thrombosis, will be evaluated at 8, 12 and 24 months.
Study: NCT00220558
Study Brief:
Protocol Section: NCT00220558