Description Module

Description Module

The Description Module contains narrative descriptions of the clinical trial, including a brief summary and detailed description. These descriptions provide important information about the study's purpose, methodology, and key details in language accessible to both researchers and the general public.

Description Module path is as follows:

Study -> Protocol Section -> Description Module

Description Module


Ignite Creation Date: 2025-12-25 @ 12:03 AM
Ignite Modification Date: 2025-12-25 @ 12:03 AM
NCT ID: NCT02738658
Brief Summary: Background: A total of 25-50% of patients with stable coronary atherosclerosis treated with metallic stent implantation remain with effort angina despite optimal medical treatment and absence of stent restenosis at 1 year. The most plausible cause of persistent effort angina after stent implantation is microcirculatory dysfunction. Coronary circulation matches the myocardial blood supply and oxygen consumption. Metallic stent implantation has been related with endothelial dysfunction and impaired coronary blood flow reserve (relation between coronary blood flow at rest and maximal hyperemia) of the treated vessel at 1 year. Bioresorbable Vascular Scaffold (BVS) has been shown to improve the endothelial function and to improve the angina symptoms at 1 year. However, the coronary blood flow of BVS has never been tested. Main objective: To determine differences in the blood average peak velocity at maximal hyperemia with adenosine infusion between patients treated with bioresorbable and metallic coronary stents at 1 year after stent implantation. Methodology: A total of 70 patients are 1:1 randomized to everolimus-eluting metallic stent (EES) versus everolimus-eluting BVS implantation in patients with stable coronary disease. At 1 year, patients undergo to invasive coronary angiography prior cessation of vasomotor drugs. A pressure/Doppler wire is advanced distally to the "treated segment" and the endothelial (acetylcholine) and non-endothelial (adenosine and nitroglycerine) vasomotor function is assessed with quantitative coronary angiography and pressure and Doppler measurements. Angina test questionnaires are obtained at different time-points of the study. Expected results: A difference between patients treated with BVS and EES of 12.0 cm/sc in the maximal average peak velocity (APV) under maximal hyperemia (with adenosine administration) is expected, as assessed by Doppler measurements, at 1 year after stent implantation. The study is powered to assess superiority in terms of maximal APV favoring patients treated with BVS.
Study: NCT02738658
Study Brief:
Protocol Section: NCT02738658