The Description Module contains narrative descriptions of the clinical trial, including a brief summary and detailed description. These descriptions provide important information about the study's purpose, methodology, and key details in language accessible to both researchers and the general public.

Description Module path is as follows:

Study -> Protocol Section -> Description Module

Description Module


Ignite Creation Date: 2025-12-25 @ 12:29 AM
Ignite Modification Date: 2025-12-25 @ 12:29 AM
NCT ID: NCT02820467
Brief Summary: Investigators conduct a monocentric pilot study with the objective to determine the hemodynamic parameter of fluorescence angiography (slope, amplitude, saturation time ) best correlated with toe pressure in patients with suspicion of critical limb ischemia.
Detailed Description: Critical limb ischemia, defined as the presence of chronic ischemic rest pain, ulcers or gangrene attributable to objectively proven arterial occlusive disease, is associated with the appalling prospect that approximately 30% will lose their leg and 25% will die at one year. Despite the progress of therapeutics these statistics haven't changed. Critical limb ischemia is a clinical diagnosis but should be supported by objective tests. None of theses tests (toe blood pressure (TBP), transcutaneous oxygen pressure (TcPO2) and skin perfusion pressure (SPP)) have proven to be enough specific or sensitive, more so they are time consuming, can be subject to several artifacts and may be in some cases discordant making diagnosis difficult. Fluorescence angiography has long been used in ophthalmology for the evaluation of the microcirculation of the retina. Infracyanine remains within the intravascular space allowing the visualization of the vasculature to a depth of 10 mm. With the Fluobeam system, images to a maximal width of 20 cm can be obtained therefore allowing the evaluation of the tissue perfusion of the entire foot. Method: Fluorescence angiography is performed in the laboratory in the same time as TCPO2, TP and SPP. Infracyanine is injected in an antecubital vein and visualization and signal acquisition carried out using a specific camera device (Fluoptic SAS, France) producing the time course of hemodynamic parameters (slope, amplitude, saturation time). 30patients will be evaluated with correlation between data obtained by fluorescence angiography and too blood pressure
Study: NCT02820467
Study Brief:
Protocol Section: NCT02820467