Description Module

Description Module

The Description Module contains narrative descriptions of the clinical trial, including a brief summary and detailed description. These descriptions provide important information about the study's purpose, methodology, and key details in language accessible to both researchers and the general public.

Description Module path is as follows:

Study -> Protocol Section -> Description Module

Description Module


Ignite Creation Date: 2025-12-25 @ 1:15 AM
Ignite Modification Date: 2025-12-25 @ 1:15 AM
NCT ID: NCT00228293
Brief Summary: Using an investigational monitor/defibrillator that passively records CPR quality parameters, including chest compression rate and depth and ventilation rate and volume, we are prospectively recording CPR quality during sequential in-hospital cardiac arrests at the University of Chicago Hospitals. Using an audio feedback system linked to this device, we are studying whether such audio feedback improves CPR quality when provided to rescuers trained in the use of the device.
Detailed Description: Patients who suffer cardiac arrest during their hospitalization at the University of Chicago hospitals are given CPR and other resuscitation measures by trained physician and nurse teams. This care is given with the use of defibrillators to monitor cardiac rhythm as well as provide defibrillation as needed. We have worked closely with engineers at Laerdal Medical Corporation to develop a defibrillator that passively monitors the quality of CPR via additional external sensors (see details in the following reference: Abella BS, Alvarado JP, Myklebust H, Edelson DP, Barry A, O'Hearn N, Vanden Hoek TL, Becker LB. Quality of cardiopulmonary resuscitation during in-hospital cardiac arrest. JAMA. 2005;293:305-10). Patients who suffer in-hospital arrest are enrolled (provided they are over 16 years of age, are not pregnant, and are not in the operating room or emergency room setting) with mechanisms to satisfy IRB waiver of consent provisions. These patients receive the same care as before the study, but CPR parameters are recorded by the device. In addition, the device provides audio/visual "coaching" in CPR, based on the actual performance of CPR as measured. We hypothesize that this coaching will improve CPR quality and hopefully improve survival from cardiac arrest. The first phase of investigation is now complete, where patients were enrolled and studied without feedback ("baseline" group). Now we are enrolling patients into a second group with feedback provided. Enrollment is nearly complete for this second group. We will then evaluate the baseline and feedback groups to ascertain whether CPR improved over the two cohorts.
Study: NCT00228293
Study Brief:
Protocol Section: NCT00228293