Viewing Study NCT02540694


Ignite Creation Date: 2025-12-25 @ 1:28 AM
Ignite Modification Date: 2026-01-02 @ 10:38 PM
Study NCT ID: NCT02540694
Status: UNKNOWN
Last Update Posted: 2015-09-04
First Post: 2015-08-31
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: EBUS vs EUS-B for Diagnosing Sarcoidosis
Sponsor: Academisch Medisch Centrum - Universiteit van Amsterdam (AMC-UvA)
Organization:

Study Overview

Official Title: Endobronchial vs. Esophageal Ultrasound for Diagnosing Sarcoidosis: A Randomized Clinical Trial; - A Standard vs. - ProCore Needle Comparison -
Status: UNKNOWN
Status Verified Date: 2015-09
Last Known Status: RECRUITING
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: Rationale:

Endosonography with mediastinal/ hilar nodal sampling is the test of choice to diagnose sarcoidosis stage I and II - in case tissue verification of noncaseating granulomas is indicated. However, the optimal endosonographic approach (endobronchial or transoesophageal) for mediastinal nodal sampling is under discussion.

Secondly, which needle size or type provides optimal tissue sample quality for granuloma detection is unknown. The novel 25 Gauge (G) beveled ProCore needle, allows tissue acquisition of small core biopsies in addition to cytological aspirates.

Hypotheses:

1. Esophageal ultrasound guided (EUS-B) sampling of intrathoracic lymph nodes has a 14% higher granuloma detection rate compared to endobronchial ultrasound (EBUS) guided nodal sampling in patients with suspected sarcoidosis stage I/II.
2. 25G ProCore needles provide superior sample quality compared to conventional 22G needles in patients with suspected sarcoidosis stage I/II.

Study design:

Investigator initiated, randomized clinical trial. Setting: International, multicenter (university and general hospitals)

Study population:

Consecutive patients with a clinical and radiologic suspicion of sarcoidosis stage I or II and an indication for tissue verification of non-caseating granulomas are eligible for inclusion.

Intervention:

EBUS vs EUS-B, simultaneously comparing the standard vs novel ProCore needles.

Main study endpoints:

1. The granuloma detection rate of endobronchial (EBUS) guided sampling of intrathoracic lymph nodes compared to esophageal (EUS-B using the EBUS scope) guided sampling in patients with suspected sarcoidosis stage I/II.
2. Sample quality of conventional 22G vs. 25G ProCore needles in patients with suspected sarcoidosis stage I/II.
Detailed Description: None

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: