Viewing Study NCT06474494


Ignite Creation Date: 2025-12-25 @ 1:40 AM
Ignite Modification Date: 2026-01-06 @ 12:27 AM
Study NCT ID: NCT06474494
Status: COMPLETED
Last Update Posted: 2024-06-26
First Post: 2024-06-19
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: Evaluation of Double Layer Application Using a Universal Adhesive in the Quality of Cervical Lesions Restorations
Sponsor: Universidad de los Andes, Chile
Organization:

Study Overview

Official Title: Clinical Evaluation of the Effect of Double Layer Application Using a Universal Adhesive in Restorations of Non-carious Cervical Lesions: Double-blind Randomized Clinical Trial
Status: COMPLETED
Status Verified Date: 2024-06
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: The aim of this study will be to evaluate the effect of a double layer application of a universal adhesive system used as etch-and-rinse application mode in non-carious cervical lesions (NCCLs), on the 6- and 12-months clinical performance.

Materials \& Methods: 144 restorations were randomly placed in 36 subjects (16 male and 20 female) according to the following groups (n=36): ER1 (one layer of Scotchbond Universal Plus adhesive applied as etch-and-rinse mode); ER2 (double layer of Scotchbond Universal Plus adhesive applied as etch-and-rinse mode); SEE1 (one layer of Scotchbond Universal Plus adhesive applied as selective enamel etching); SEE2 (double layer of Scotchbond Universal Plus adhesive applied as selective enamel etching). All groups were light-cured for 10s/1,000 mW/cm2 only after final layer. A resin composite will be placed by applying three increments and each one will be light cured for 20s/1,000 mW/cm2. The restorations will be finished immediately with fine diamond burs and polishers. The restorations will be evaluated at baseline and after 6- and 12-months by using the FDI criteria. The following outcomes will be evaluated: retention, marginal staining, marginal adaptation, post-operative sensitivity and recurrence of caries. The differences among the groups will be calculated using Friedman repeated measures analysis of variance rank (α = 0.05).
Detailed Description: This is a four-arm, double-blind, randomized controlled clinical trial. Experimental group 1: 35 non-carious cervical lesions (NCCL) will receive composite resin restorations applying a double layer of Scotchbond Universal Plus adhesive applied as etch-and-rinse mode.

Experimental group 2: 35 non-carious cervical lesions (NCCL) will receive composite resin restorations applying a double layer of Scotchbond Universal Plus adhesive applied as selective enamel etching mode.

Control group 1: 35 non-carious cervical lesions (NCCL) will receive composite resin restorations applying one layer of Scotchbond Universal Plus adhesive applied as etch-and-rinse mode.

Control group 2: 35 non-carious cervical lesions (NCCL) will receive composite resin restorations applying one layer of Scotchbond Universal Plus adhesive applied as selective enamel etching mode.

LCNCs will be randomized to application mode and number of layers. All groups will be light-cured with a light-curing device (SmartLite Focus, Dentsply) with a light intensity of 900 mW/cm² for 10 seconds. Operators will restore the cervical area by applying three increments of resin (Filtek Supreme XT, 3M). Each increment will light cure for 20 s at 900 mW/cm2 (SmartLite Focus, Dentsply). Restorations will be finished immediately with fine and extra fine diamond burs and polished with polishing spirals.

Study Oversight

Has Oversight DMC: True
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: