Viewing Study NCT02523534


Ignite Creation Date: 2025-12-25 @ 2:24 AM
Ignite Modification Date: 2026-01-08 @ 9:12 PM
Study NCT ID: NCT02523534
Status: COMPLETED
Last Update Posted: 2023-11-07
First Post: 2015-08-05
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: Utilizing a Novel Method to Map Sources of Atrial Fibrillation
Sponsor: Northwestern University
Organization:

Study Overview

Official Title: Pathophysiological Significance of Atrial Fibrillation Electrogram Patterns
Status: COMPLETED
Status Verified Date: 2023-11
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: This is an electrogram mapping study that tests the ability of a new signal processing technique called electrogram morphology recurrence mapping to locate drivers in participants with atrial fibrillation. This study will also test the hypothesis that there are non-invasive markers that can predict driver location. Electrogram mapping will be performed in participants undergoing ablation for persistent atrial fibrillation. These participants will have a cardiac MRI and 12-lead ECG prior to the ablation procedure.
Detailed Description: Atrial fibrillation (AF) has been described as a new emerging epidemic currently affecting around 1% of the population. Risk of AF increases with age and as the elderly continue to comprise a larger percentage of the population in the United States, the health burden of AF continues to increase. Some estimates project nearly 16 million cases of AF in the US alone by 2050. The economic burden of AF has been estimated to be between $6-26 billion. AF is a significant risk factor for stroke if left untreated as well as mortality. The diagnosis and treatment of AF have therefore become an important aspect of cardiovascular medicine.

Current pharmacological treatments for AF have modest efficacy and suffer from potentially life-threatening side effects. Current ablative and surgical approaches to AF, though somewhat more successful, use an anatomic, 'one-size fits all' strategy (with some minor variations) that does not address the specific mechanisms underlying this complex arrhythmia. The pulmonary veins have been shown to be a common location of AF triggers. Thus, the most common approach for catheter ablation involves the isolation of the pulmonary veins, such as the wide area circumferential pulmonary vein ablation strategy. The lack of consideration of specific sources may be, at least in part, responsible for post- ablation arrhythmias occurring in up to 40% of patients who undergo pulmonary vein ablation. However, while ablation/surgical success has been shown to increase with more extensive ablation/surgery in the atria, the latter comes at the cost of significant "collateral damage" to the atrial myocardium as well as to surrounding structures, with an accompanying increase in the risk of complications and a decrease in atrial function. The time and cost to perform these procedures is also significant. Thus, catheter and surgical ablation strategies tailored to the specific arrhythmia origin of a patient's AF would have a significant impact on the ability to treat this arrhythmia.

The investigator's laboratory has developed a novel electrogram morphology recurrence analysis to observe the nonlinear dynamics of AF activation. This technique to map AF activation is based on the hypothesis that AF electrograms with morphologies that are highly recurrent and that have short cycle lengths represent the locations of stable AF sources. The investigator's preliminary data show that when the highest recurrence percentage or shortest recurrence cycle length occurs in the left atrium in patients undergoing pulmonary vein-based ablation, the patients has a much higher chance to stay in sinus rhythm post-ablation than when the highest recurrence percentage or shortest recurrence cycle length occur in the right atrium. Cycle length of all activations was not a predictor of outcomes. High resolution electrical mapping of AF in the canine atria showed that the shortest recurrence cycle length sites correspond to areas containing rotors. Thus, these preliminary data provide strong evidence that morphology recurrence mapping is able to identify the locations of AF sources.

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?:

Secondary ID Infos

Secondary ID Type Domain Link View
1R01HL125881-01A1 NIH None https://reporter.nih.gov/quic… View