Viewing Study NCT05881733


Ignite Creation Date: 2025-12-25 @ 2:42 AM
Ignite Modification Date: 2026-01-10 @ 7:08 PM
Study NCT ID: NCT05881733
Status: COMPLETED
Last Update Posted: 2025-12-04
First Post: 2023-05-21
Is Gene Therapy: True
Has Adverse Events: True

Brief Title: Effect of a Bigger Cryoballoon on the Total Antral Lesion Size: Evaluation of POLARx FIT
Sponsor: Erasmus Medical Center
Organization:

Study Overview

Official Title: Effect of a Bigger Cryoballoon on the Total Antral Lesion Size: Evaluation of POLARx FIT
Status: COMPLETED
Status Verified Date: 2025-11
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: BETTER-FIT
Brief Summary: The investigators will prospectively evaluate the extent of antral lesion created by the 31 mm balloon size of a novel cryoballoon catheter (POLARx FIT). In 20 patients with paroxysmal atrial fibrillation, the investigators will perform pre- and post-ablation high-definition 3D maps to quantify the extent of lesion created by the 31 mm POLARx FIT cryoballoon.
Detailed Description: Rationale: The next generation POLARx cryoablation balloon (CB) catheter will have the option of to deliver cryotherapy with the current balloon size of 28 mm or a new, larger 31 mm size by changing the inner balloon pressure (POLARx FIT, Boston Scientific). Currently, there is no data on the extension of left atrial (LA) lesion formation with the 31 mm balloon size of the POLARx FIT cryoablation balloon catheter. The hypothesis is that a larger CB size results in a wide antral circumferential lesion.

Objective: The primary objective is to evaluate the antral lesion size using ultrahigh-density (UHDx) mapping pre- and post-cryoablation with the 31 mm balloon size CB. Secondary objectives are the proportion of pulmonary veins (PVs) where a 31 mm CB could be positioned to achieve a grade 4 occlusion and the single shot success rate with the 31 mm balloon size CB.

Study design: Single-center, single-arm, prospective study with pre- and post-PVI UHDx mapping.

Study population: Twenty adult patients with paroxysmal AF who are scheduled to undergo pulmonary vein isolation (PVI) with a CB.

Intervention: Patients will undergo pre- and post-ablation UHDx mapping (Orion catheter and Rhythmia 3D-mapping system, Boston Scientific) during the index procedure.

Main study parameters/endpoints: The primary endpoint is the extent of the antral lesion size. Secondary endpoints are the proportion of PVs with grade 4 occlusion with the 31 mm balloon size CB, the single shot success rate of the 31 mm balloon size CB, difference in rate of achieving grade 4 occlusion in comparison to the standard (28 mm) size.

Nature and extent of the burden and risks associated with participation, benefit, and group relatedness: A UHDx mapping will be acquired before and after complete PVI. The procedures will be performed under deep sedation, which is standard practice for CB procedures in our institution. The risk of additional mapping is limited. LA mapping is a standard diagnostic method for patients undergoing PVI with radiofrequency ("standard-of-care"). In the current study, UHDx mapping will now be used in patients undergoing PVI with CB. The most important complication of additional intracardiac mapping is cardiac tamponade, but this risk is low (\<0.5%).

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?:

Secondary ID Infos

Secondary ID Type Domain Link View
NL84423.078.23 REGISTRY CCMO View