Viewing Study NCT04170933


Ignite Creation Date: 2025-12-25 @ 3:00 AM
Ignite Modification Date: 2026-01-17 @ 2:49 AM
Study NCT ID: NCT04170933
Status: UNKNOWN
Last Update Posted: 2022-05-17
First Post: 2019-11-15
Is Gene Therapy: True
Has Adverse Events: False

Brief Title: Magnetic Compression Anastomosis for Recanalization of Biliary Stricture
Sponsor: First Affiliated Hospital Xi'an Jiaotong University
Organization:

Study Overview

Official Title: A Prospective Study: Magnetic Compression Anastomosis for Recanalization of Biliary Stricture
Status: UNKNOWN
Status Verified Date: 2022-04
Last Known Status: RECRUITING
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: Biliary stricture is a common complication after end-to-end biliary anastomosis, especially after liver transplantation. This study is designed to investigate the safety and efficacy of magnetic recanalization technique, a newly clinical method, for treating biliary anastomotic stricture.
Detailed Description: Biliary anastomotic stricture is a common complication of after end-to-end biliary anastomosis. Magnetic recanalization is a promising way to establish connection of biliary tract after stenosis or completed obstruction. This study is designed to investigate the safety and efficacy of magnetic recanalization among patients with severe biliary stricture after biliary anastmosis. Patients who failed to undergo stent placement with endoscopic retrograde cholangiopancretography (ERCP) would be enrolled for magnetic recanalization treatment. Magnetic treatment will be implemented by several steps. Firstly, placement of one magnet through the sinus of percutaneous transhepatic cholangio drainage (PTCD) in upper part of the bile duct; Second, introduction of another magnet via ERCP into the distal part of the bile duct, and making them be mated together; Third, after necrosis of the tissue between the two magnets, the magnets will drop off and be taken out together through the thread connected with them out of the mouth. Last, a plastic stent should be placed in the bile duct for a lasting support. The time of recanalization (drop off of the magnets), and adverse events (e.g. fever, melena, nausea, vomiting, anorexia, hematemesis, abdominal pain, and gastrointestinal bleeding) will be recorded, and each patient will be followed up for long-term outcomes.

Study Oversight

Has Oversight DMC: True
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: