Viewing Study NCT02081105


Ignite Creation Date: 2025-12-25 @ 3:30 AM
Ignite Modification Date: 2025-12-26 @ 2:12 AM
Study NCT ID: NCT02081105
Status: TERMINATED
Last Update Posted: 2022-01-11
First Post: 2014-02-27
Is NOT Gene Therapy: False
Has Adverse Events: False

Brief Title: Validation of Digital Chest-X-ray (CXR) to Assess Lung Recruitment in ARDS
Sponsor: Hospices Civils de Lyon
Organization:

Study Overview

Official Title: Bedside Assessment of PEEP-induced Lung Recruitment by Using Digital Chest-X-ray in ARDS Patients. A Multicenter Prospective Study.
Status: TERMINATED
Status Verified Date: 2022-01
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: The study stopped because it was difficult to recruit the 130 expected patients
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: RECRUTEX
Brief Summary: Lung recruitability is essential for optimal Positive end-expiratory pressure (PEEP) selection in ARDS patients. It is defined as the potential for the non aerated or poorly aerated lung mass to become aerated due to the increase in airway pressure. PEEP contributes to lung recruitment mostly by maintaining some amount of the end-inspiratory recruitment at the end of expiration. PEEP also stabilizes patency of the small airways and minimizes the repeated opening and closing of them during the breathing cycle, which is implicated in a further lung inflammation. The gold-standard method for assessing lung recruitability is lung CT scan. For economic and feasibility this technique cannot be used in routine. Therefore, techniques that can be used at the bedside to measure lung recruitability are very well known. The measurement of recruited lung volume (Vrec) by using pressure-volume curve generated by the ventilator is another reference method to approach lung recruitment. It can be done at the bedside. Chest-X-Ray (CXR) is an interesting option as done in routine in this setting. Furthermore, it allows quantifying aeration thanks numerical image processing and a regional approach. In a preliminary one-center study we found a significant negative correlation between the amount of Vrec and the reduction in lung density measured by digital CXR between 5 and 15 cm H2O PEEP. In present study we would like to extend this previous result on a larger number of patients in a multicenter investigation.
Detailed Description: None

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: