Brief Title: Clinical and Radio-graphic Evaluation of Non-staining Bio-active Bio-ceramic (Neo MTA 2) in Revascularization
Sponsor: Cairo University
Organization:

Study Overview

Official Title: Clinical and Radio-graphic Evaluation of Bio-active Bio-ceramic (Neo MTA 2) Versus White MTA Used as Coronal Plug Material in Revascularization of Non-vital Immature Permanent Anterior Teeth: A Randomized Clinical Trial
Status: NOT_YET_RECRUITING
Status Verified Date: 2024-10
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: The study will compare the clinical and radio-graphic performance of newly introduced non-staining bio-active bio-ceramic (Neo MTA 2) versus White MTA used as coronal plug material in revascularization of non-vital immature permanent anterior teeth.Visual examination, palpation, A measuring scale in digital radio-graph software (DIGORA for Windows software) will be used for evaluation.
Detailed Description: Mineral trioxide aggregate (MTA) has been widely used in revascularization procedures for coronal sealing in more than 85% of studies for privilege of bio compatibility, good sealing properties, and marginal adaptation. However, its poor handling characteristics and potential coronal discoloration effects are the major disadvantages of using mineral trioxide aggregate.

Although white MTA (WMTA) has been developed to overcome the tooth discoloration caused by the application of grey MTA, several in vivo and in vitro studies have also reported tooth discoloration after using WMTA.

To overcome the problems associated with WMTA, a new modification was introduced to the market called NeoMTA 2 as a new hope to overcome the discoloration problem. NeoMTA 2 provides easier handling, shorter setting time, and better color. The lack of post-operative discoloration problems was mainly due to the absence of Bismuth oxide in NeoMTA.

up to date, no clinical trials have reported the clinical and radio-graphic outcomes after revascularization of non-vital immature permanent anterior teeth using Neo MTA 2. Thus, the present study aims to evaluate and compare clinically and radio-graphically the effect of using two different coronal plug materials (Neo MTA 2 versus White mineral trioxide aggregate) in revascularization of non-vital immature permanent anterior teeth.

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: True
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: True
Is an FDA AA801 Violation?: