Viewing Study NCT01783002


Ignite Creation Date: 2025-12-25 @ 4:03 AM
Ignite Modification Date: 2025-12-26 @ 2:57 AM
Study NCT ID: NCT01783002
Status: UNKNOWN
Last Update Posted: 2015-09-18
First Post: 2013-01-04
Is NOT Gene Therapy: False
Has Adverse Events: False

Brief Title: 11C Methionine PET for the Detection of Hyperfunctional Parathyroid Tissues
Sponsor: University of British Columbia
Organization:

Study Overview

Official Title: Pre-operative Parathyroid Imaging: a Comparison of 11C-Methionine PET, 18F-FDG PET AND SPEC-CT for the Detection of Hyperfunctional Parathyroid Tissues
Status: UNKNOWN
Status Verified Date: 2015-09
Last Known Status: RECRUITING
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: The overall sensitivity and specificity of 11C-MET PET/CT is superior to 18F-FDG PET/CT and conventional SPECT-CT for the detection of abnormal parathyroid glands.
Detailed Description: STUDY OBJECTIVES Primary: To compare the accuracy, sensitivity and specificity of 11C-methionine (MET) PET/CT and 99mTc-MIBI SPECT-CT in the detection of pathologic parathyroid glands in patients with primary hyperparathyroidism.

Secondary:To compare the accuracy, sensitivity and specificity of 11C-MET and 18F-FDG PET/CT scans in the detection of pathologic parathyroid glands in patients with primary hyperparathyroidism.

STUDY DESIGN A phase II diagnostic imaging, single-centre study to compare the accuracy of 11C-MET PET/CT with standard 99mTc-MIBI SPECT-CT and with 18F-FDG PET/CT imaging in patients with primary hyperparathyroidism.

STUDY POPULATION Number of Subjects: 50 patients Number of groups: 1: 50 with primary hyperparathyroidism. Age/Gender: Age greater than or equal to 19 years / Male and Female Study specific requirements: Subjects with clinically suspected primary hyperparathyroidism who require 99mTc-MIBI SPECT-CT parathyroid imaging.

INVESTIGATIONAL PRODUCT Product: 11C-Methionine Route of administration: Intravenous Dosage(s) and frequency: Radioactive dose of 11C-Methionine of 6 MBq per kilogram body weight per injection (maximum dose of 555 MBq); one injection per patient.

COMPARATOR PRODUCTS Product: 99mTc-Methoxyisobutylisonitrite; 18F-Fluorodeoxyglucose Route of administration: Intravenous Dosage(s) and frequency: (1) Radioactive dose of 99mTc-Methoxyisobutylisonitrite of 555 - 740 MBq per injection; one injection per patient. (2) Radioactive dose of 18F-Fluorodeoxyglucose of 296 - 521 MBq per injection; one injection per patient.

EVALUATION CRITERIA Efficacy: The comparison of the accuracy, sensitivity, and specificity of 11C-MET PET/CT with 99mTc-MIBI SPECT-CT and 18F-FDG PET/CT in the detection of pathologic parathyroid glands in patients with primary hyperparathyroidism.

Safety: Vital signs before and following 11C-MET administration; adverse events collection.

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: