Viewing Study NCT01333618


Ignite Creation Date: 2025-12-25 @ 4:41 AM
Ignite Modification Date: 2025-12-26 @ 3:43 AM
Study NCT ID: NCT01333618
Status: COMPLETED
Last Update Posted: 2011-04-26
First Post: 2011-04-04
Is NOT Gene Therapy: False
Has Adverse Events: False

Brief Title: Introducer Curving Technique for Tilt of Transfemoral Günther Tulip Inferior Vena Cava Filter
Sponsor: China Medical University, China
Organization:

Study Overview

Official Title: Introducer Curving Technique for Tilt of Transfemoral Günther Tulip Inferior Vena Cava Filter:A Randomized Double-Blind Comparison
Status: COMPLETED
Status Verified Date: 2008-08
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: It has been demonstrated that implantation of inferior vena cava filter was safe and effective in the prevention or reduction of fatal pulmonary thromboembolism in numerous clinical researches. When acute deep venous thrombosis need transcatheter thrombolysis, transfemoral Günther Tulip Filter implantation could avoid catheter across the Günther Tulip Filter. Although incidence of significant filter tilting (\>10°) is not high (13%-16%), severe tilting of the Günther Tulip Filter may be associated with difficulty or sometimes impossibility of retrieval. It has been reported that a simple technique of keeping tension of the delivery system may prevent significant tilting of the transjugular Günther Tulip Filter in an in-vitro study. But no clinical study of prevention transfemoral Günther Tulip Filter from tilting has been reported. The investigators conducted a randomized, controlled study to test whether the introducer curving technique is useful to decrease the extent of tilting of transfemoral Günther Tulip Filter.
Detailed Description: The study was designed as a double-blind randomized controlled trial, with research assessors and patients intended to be blind to the intervention status. The staff members performing the assessment were not involved in implementing any aspect of the intervention. 108 patients were randomized to accept curving introducer Günther Tulip Filter and transcatheter thrombolysis or straight introducer Günther Tulip Filter and transcatheter thrombolysis. The assessments include the tilting angle between the axes of inferior vena cava and Günther Tulip Filter after implantation; the tilting angle between the axes of inferior vena cava and Günther Tulip Filter before retrieval; the fluoroscopy time of Günther Tulip Filter retrieval; the rate of retrieval hook adhering vascular wall; the success rate of retrieval.

Study Oversight

Has Oversight DMC: True
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: