Viewing Study NCT02208518


Ignite Creation Date: 2025-12-25 @ 5:04 AM
Ignite Modification Date: 2025-12-26 @ 4:07 AM
Study NCT ID: NCT02208518
Status: COMPLETED
Last Update Posted: 2014-08-05
First Post: 2014-03-04
Is NOT Gene Therapy: False
Has Adverse Events: False

Brief Title: Quantitative And Qualitative Eus Elastography
Sponsor: Instituto Ecuatoriano de Enfermedades Digestivas
Organization:

Study Overview

Official Title: Could Quantitative And Qualitative EUS-Elastography Results Be Affected By The Compression Rate And The Diameter Of The Region Of Interest (ROI)?
Status: COMPLETED
Status Verified Date: 2014-08
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: Endoscopic ultrasonography is considered the most accurate methods for the diagnosis and staging of chronic inflammatory and neoplastic pancreatic diseases. Differential diagnosis of solid pancreatic masses, however, remains a challenge and endoscopic ultrasound-guided fine needle aspiration is necessary. Recently, Endoscopic ultrasound elastography has been introduced as an alternative method to evaluate tissue stiffness of solid pancreatic masses, being an index of tissue elasticity, which may be related to histopathology features (hard tissue = blue = neoplastic and soft tissue = red-yellow-green = non-neoplastic). However, recently publications show different results using elastography. Moreover, a lack of data in Endoscopic ultrasound-elastography exist regarding the compression rate of the probe and the diameter of the region of interest under analysis in previously studies that by physics could affect the tissue elasticity.

Based on the hypothesis that elastography could be affected by compression rate of the probe and the diameter of the region of interest analyzed the present study aimed to evaluate the quantitative (strain ratio) and qualitative endoscopic ultrasound-elastography results determined by the compression rate of the probe (measured by the curve of compression in the second generation of elastography) and the diameter of the region of interest in normal pancreatic tissue.
Detailed Description: prospective study performed in patients undergoing for upper-endoscopic ultrasound from October 31-to end of November 2013. Endoscopic ultrasound-elastography was performed using linear Pentax-EUS and "Hitachi-Avius". The quantitative-strain ratio and qualitative endoscopic ultrasound-elastography was measured in the body of the pancreas taking in consideration the curve of the compression rate of the probe high: +0.4, middle: 0, low: -0.4 in the largest and smaller region of interest diameters. Analysis for qualitative elastography was obtained by the predominant color of the pancreatic area studied. Pictures where recorded and quantitative strain ratio data were calculated comparing endoscopic ultrasound-elastography of pancreatic tissue with soft tissue (normal mucosal layer: red). Finally, a comparative analysis was performed between the results with the mean normal value for quantitative strain ratio previously published for normal pancreatic tissue, and between the different compression rates of the probe.

Study Oversight

Has Oversight DMC: True
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: