Viewing Study NCT00170014



Ignite Creation Date: 2024-05-05 @ 11:55 AM
Last Modification Date: 2024-10-26 @ 9:16 AM
Study NCT ID: NCT00170014
Status: COMPLETED
Last Update Posted: 2011-02-15
First Post: 2005-09-12

Brief Title: Precision of the Magnetocardiographer for Data Aquision and Analysis
Sponsor: Mayo Clinic
Organization: Mayo Clinic

Study Overview

Official Title: Reproducibility of Magnetocardiography Measurements Using the Cardiomag Magnetocardiograph System Model 2409 and Its Software for Data Acquisition and Analysis
Status: COMPLETED
Status Verified Date: 2011-02
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: magnetocardiography has been extensively studied focusing on the possible clinical applications of the device Evaluating the precision of a device is a prerequisite condition to know what are significant changes and how can these be trusted A respectable reproducibility study for the MCG measurements is crucial for this new device to be used for clinical applications In this study we will focus on a critical portion of the heart cycle assessing for changes in time of the computerized analysis of this phase and comparing the analysis done by two examiners
Detailed Description: The studies involving magnetocardiography have almost exclusively focused on evaluating possible clinical applications of the device Leder et al saw the need for investigating the reproducibility of High Temperature Superconducting HTS-MCG measurements They tested 18 healthy volunteers stating that assessment of the reproducibility of HTS-MCGs in the normal heart is a prerequisite condition for the definition of significant levels of changes which for instance may be observed in serial measurements of patients suffering from acute coronary syndromes They also pointed out the potentially strong electromagnetic interference inside a hospital likely to be very different from the noise found in engineering laboratories where the MCGs are originally calibrated and tested A respectable reproducibility for the MCG measurements is crucial for clinical applications Leder et al studied the reproducibility of QRS complexes ST segments and T waves They found that the reproducibility of the measurements in the depolarization phase was high whereas the reproducibility of their repolarization readings was considerably lower The results led Leder et al to conclude that further technical development was needed to improve signal-to-noise ratio allowing for clinical application of repolarization abnormalities for recognizing Acute Coronary Syndromes In this study we will focus on the repolarization phase by assessing the reproducibility of the T wave only Comparison of scores and results based on computer analyses will provide the basis for our evaluation Visual interpretations by the two examiners will also be compared

Study Oversight

Has Oversight DMC: None
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: None