Viewing Study NCT04365192


Ignite Creation Date: 2025-12-24 @ 3:22 PM
Ignite Modification Date: 2025-12-24 @ 3:22 PM
Study NCT ID: NCT04365192
Status: COMPLETED
Last Update Posted: 2020-04-29
First Post: 2020-04-17
Is Possible Gene Therapy: False
Has Adverse Events: False

Brief Title: Comparison of Efficacy of Two Supraglottic Airway Devices: I-gel and the Self-pressurized Air-q in Elderly Patients
Sponsor: Istanbul Medeniyet University
Organization:

Study Overview

Official Title: Comparison of Efficacy of Two Supraglottic Airway Devices: I-gel and the Self-pressurized Air-q in Elderly Patients
Status: COMPLETED
Status Verified Date: 2020-04
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: Supraglottic airway devices with noninflatable cuff have advantages in omitting the cuff pressure monitoring and reducing potential pharyngolaryngeal complications. Typical devices without cuff inflation available are the i-gel™ and the self-pressurized air-Q™ intubating laryngeal airway (air-Q SP).

The i-gel airway is a supraglottic airway management device made of thermoplastic elastomer, which is soft, gel-like, and transparent. It was designed to create a noninflating anatomical seal of the pharyngeal, laryngeal, and perilaryngeal structures while avoiding the compression trauma that can occur with inflatable SADs.

The i-gel has evolved as a device that accurately positions itself over the laryngeal framework, providing a reliable perilaryngeal seal, and therefore no cuff inflation is necessary. Its advantages include easier insertion, minimal risk for tissue compression, and stability after insertion.

The air-Q is a new SAD intended for use as a primary airway and an aid for tracheal intubation in situations of anticipated or unanticipated difficult airways. The intracuff pressure of air-Q dynamically equilibrates with the airway pressure and adjusts to the patient's pharyngeal and periglottic anatomy, potentially providing improved airway fit and seal.

The anatomical and physiological changes that accompany ageing may have a significant influence on the efficacy and safety of SADs. The distinctive features of the air-Q SP and i-gel may lead to a substantial difference in performance in the elderly, and it is planned a head-to-head comparison of these two devices in patients aged between 65 and 85 years.
Detailed Description: None

Study Oversight

Has Oversight DMC: None
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: