Viewing Study NCT06546592


Ignite Creation Date: 2025-12-24 @ 3:52 PM
Ignite Modification Date: 2025-12-24 @ 3:52 PM
Study NCT ID: NCT06546592
Status: RECRUITING
Last Update Posted: 2025-03-11
First Post: 2024-07-25
Is Possible Gene Therapy: False
Has Adverse Events: False

Brief Title: Locally Optimised Contouring With AI Technology for Radiotherapy
Sponsor: Royal North Shore Hospital
Organization:

Study Overview

Official Title: LOCATOR - Locally Optimised Contouring With AI Technology for Radiotherapy
Status: RECRUITING
Status Verified Date: 2025-03
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: LOCATOR
Brief Summary: LOCATOR is a multicentre phase II randomised clinical trial that is looking at the process of contouring in radiation treatment for breast cancer patients. This study looks at whether contouring aided by artificial intelligence (AI) is comparable in quality to that of contouring done completely manually by a radiation oncologist. We are also looking at whether AI assisted contouring saves radiation oncologists time when compared to fully manual contouring.

LOCATOR uses the LOCATOR software which is an in-house software developed locally and trained on local data.
Detailed Description: LOCATOR is a multicentre phase II non-inferiority randomised controlled trial looking at comparing AI assisted contours (with in-house LOCATOR software) against fully manual contouring in breast cancer patients. The primary endpoint is to show non inferiority in grade of AI assisted contouring when compared to fully manual contouring with a poor contour (score \<= 2) as per the MD Anderson Contouring Grade Scale. Secondary endpoints include geometric assessments of contour accuracy, dosimetric differences based on contours, performance (geometric) when compared to commercially available tools as well as economic cost-benefit analysis if in-house AI contouring tools.

The study will randomise patients 3:1 to the intervention arm of LOCATOR assisted contours to manual contours. An initial AI contouring model for each tumor type will be trained on contours from 45 previous breast cases using a nnUNetv2 framework. The model will then be iteratively updated every 20-50 patients.

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: