Viewing Study NCT02917668


Ignite Creation Date: 2025-12-24 @ 5:52 PM
Ignite Modification Date: 2026-02-03 @ 3:13 PM
Study NCT ID: NCT02917668
Status: COMPLETED
Last Update Posted: 2018-05-11
First Post: 2016-09-25
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: Evaluation of the Risk of Hyperoxia-induced Hypercapnia in Obese Cardiac Surgery Patients
Sponsor: Laval University
Organization:

Study Overview

Official Title: Evaluation of the Risk of Hyperoxia-induced Hypercapnia in Obese Patients in a Cardiac Surgery Postoperative Setting
Status: COMPLETED
Status Verified Date: 2018-05
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: This study aims to evaluate the risk of hyperoxia-induced hypercapnia in post-op obese cardiac surgery patients. It will compare two oxygenation modes in terms of their effect on the arterial partial pressure of carbon dioxide (PaCO2) : manual titration of oxygen delivery for a peripheral oxygen saturation (SpO2) target of \> or = 95 % versus automatic titration by a closed-loop system for a SpO2 target of 90%. 15 post-op obese cardiac surgery patients will be recruited and each will receive both interventions (cross-over design). The main outcome will be the PaCO2, which will be compared after each study period. The research hypothesis is that the usual SpO2 target of \> or = 95 % is associated with a greater PaCO2 compared with a lesser SpO2 target of 90%.
Detailed Description: This study aims to evaluate the risk of hyperoxia-induced hypercapnia in post-op obese cardiac surgery patients.

The investigators will compare two oxygenation modes in terms of their effect on PaCO2 : a SpO2 target of \> or = 95 % achieved with manual titration (usual practice) and a more conservative SpO2 target of 90 % achieved with automatic titration by a closed-loop system (FreeO2).

The choice of a SpO2 target of 90 % is consistent with recent guidelines issued by the British Thoracic Society and the Thoracic Society of Australia and New Zealand, which both recommend a SpO2 target of 88-92 % for morbidly obese patients (BMI \> 40 kg/m2).

FreeO2 is a closed-loop oxygen delivery system which adjusts the oxygen flow according to the patient's real-time SpO2 and a target programed by the physician. The system also records data on heart rate, respiratory rate and SpO2. Its safety and efficacy have been tested in healthy subjects as well as in patients suffering from COPD or acute respiratory distress in the emergency room, with promising results.

The research hypothesis is that the usual SpO2 target of \> or = 95 % is associated with a greater PaCO2 compared with a lesser SpO2 target of 90%.

30 obese patients will be recruited\* at the Institut universitaire de cardiologie et de pneumologie de Québec. A written consent from the patient will be obtained the day before the surgery. The protocol has been submitted to and approved by the establishment's ethics committee.

The study will compare the effect of two different oxygenation modes on the patients' PaCO2 immediately after extubation :

FreeO2 mode : oxygen delivered by nasal cannula or Venturi mask (if flow \> 5L/min during \> 5 minutes), automatically titrated for a SpO2 of 90 +/- 2 %

Usual mode : oxygen delivered by Venturi mask, manually titrated for a SpO2 superior or equal to 95 % (the local protocol is to deliver a post-extubation FiO2 which is 10 % superior to the pre-extubation FiO2)

Patients meeting all of the eligibility criteria will be randomized in the postoperative period. After extubation, they will receive oxygen for 30 minutes according to FreeO2 mode or the usual mode, depending on randomization. After 30 minutes, a first arterial blood gas will be obtained through their arterial cannula. Next, they will be oxygenated according to the second oxygenation mode for another 30 minutes, after which a second arterial blood gas will be obtained. Each patient will thus act as his own control (cross-over design).

When patients will be oxygenated according to the usual mode, FreeO2 will be in recording mode, but will not be delivering any oxygen.

The study will last 1h for each patient, and will have to begin within 30 minutes after extubation. A member of the research team will be at the patient's bedside for the whole data collecting period.

Complete data collection should be achieved within 12 months.

Demographic data (age, sex, weight, height and BMI) will be collected upon study entering as well as pre-operative room air PCO2 on capillary blood gas, type of surgery (number of bypass grafts, extracorporal circulation time), opiates dosage per-op and post-op, and pre-op left ventricular ejection fraction and renal function. FreeO2 will be recording respiratory rate, heart rate and SpO2 for the whole study duration. The respiratory rate will also be recorded manually and on the monitor. When patients will be receiving oxygen from FreeO2, the system will record the delivered flow ; with the usual mode, the staff will record the delivered FiO2. At the end of each intervention, hemodynamic measures will be taken : systolic, diastolic and median arterial blood pressure, systolic, diastolic and median pulmonary artery pressure and amine level.

\*Initially, 15 patients were supposed to be included. After inclusion of those 15 patients, statistical analyses showed a lack of statistical power and a possibly significant difference in PaCO2, but only in half the patients. We thus submitted a protocol amendment to our institution's ethics committee to enlarge the sample size to 30 patients, which was accepted on July 13th, 2017.

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: