Viewing Study NCT02619357


Ignite Creation Date: 2025-12-24 @ 7:02 PM
Ignite Modification Date: 2025-12-25 @ 4:36 PM
Study NCT ID: NCT02619357
Status: COMPLETED
Last Update Posted: 2017-05-15
First Post: 2015-08-27
Is NOT Gene Therapy: False
Has Adverse Events: False

Brief Title: Method Validation Study to Explore the Sensitivity of SenseWear Armband Gecko for Measuring Physical Activity in Subjects With Chronic Obstructive Pulmonary Disease (COPD) & Asthma
Sponsor: GlaxoSmithKline
Organization:

Study Overview

Official Title: A Method Validation, Single-period, Open-label Evaluation Study to Explore the Sensitivity of a Novel Biosensor Device (SenseWear Armband Gecko) for Measuring Physical Activity in Subjects With COPD & Asthma
Status: COMPLETED
Status Verified Date: 2017-05
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: The prevalence, low cost, and low burden of wearable devices that provide quantitative and qualitative feedback on a subject's activity level present an opportunity for the use of these devices in clinical and observational studies. However, the accuracy and reproducibility of any given device may vary with device design and algorithm implementation. Therefore, validation of emerging technologies against known standards such as analysis of exhaled breath and currently available medical devices is critical. This is a single center, two-cohort, single period, open-label, methodology study. No investigational product will be used in this study. Eligible subjects will wear 2 generations of SenseWear Armband devices, 2 ActiGraph GT9x devices (one on the wrist and one on the waist) and a Garmin Vivofit 2 activity tracker wristband for up to 24 hours per day. Subjects who consent to participate in an optional sub-study will wear a SOMNOwatch Plus EEG-6 device while sleeping. Subjects will perform a variety of laboratory and field-based exercise tests and strength exercises using Latex-Free Therabands.The co-primary objectives of this study are firstly to compare the outputs of the test devices (SenseWear Armband Gecko and Actigraph GT9x) to those of the SenseWear Armband MF and secondly to assess the sensitivity and accuracy of the test devices in subjects with COPD or asthma while performing laboratory-based exercise testing.
Detailed Description: None

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: