Viewing Study NCT03110003


Ignite Creation Date: 2025-12-24 @ 7:23 PM
Ignite Modification Date: 2025-12-25 @ 5:03 PM
Study NCT ID: NCT03110003
Status: COMPLETED
Last Update Posted: 2018-12-19
First Post: 2017-03-30
Is NOT Gene Therapy: False
Has Adverse Events: True

Brief Title: Bupivacaine With Epidural Volume Extension
Sponsor: University of Alabama at Birmingham
Organization:

Study Overview

Official Title: Comparing Low-dose Bupivacaine With Epidural Volume Extension to Standard Bupivacaine Dosing for Short Obstetric Procedures: A Prospective, Randomized Study
Status: COMPLETED
Status Verified Date: 2018-11
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: In this study the investigator will address the efficacy of using low dose bupivacaine spinal anesthesia (SA) in combination with epidural volume extension (EVE) for patients undergoing short obstetric procedures.
Detailed Description: Due to risks to both the mother and fetus, neuraxial anesthesia - spinal, epidural, or combined spinal-epidural (CSE) - is preferred over general anesthesia for all obstetrical procedures. However, one downside to neuraxial anesthesia is the increased time patients have to stay in the post-anesthesia care unit (PACU) due to residual numbness from the neuraxial block. In this study, the investigators will address the efficacy of using low dose bupivacaine spinal anesthesia (SA) in combination with epidural volume extension (EVE) for patients undergoing short obstetric procedures. This will be accomplished by performing a CSE with: 1) injecting the local anesthesia in the spinal space; 2) injecting sterile saline into the epidural space to help increase the spread of the local anesthesia in the spinal space. The idea is that physicians will be able to use less local anesthetic due to getting a greater spread of medication. This lower amount of local anesthetic will lead to a decreased duration of the spinal block; therefore, it will significantly decrease PACU length of stay. This technique will be compared to our traditional dose of spinal anesthetic without EVE in the CSE. Both groups will have an epidural catheter in place to allow us to give any additional local anesthetic to keep the patient comfortable throughout the procedure if the spinal anesthesia begins to wear off. The aim of this study is to determine if low dose spinal bupivacaine in conjunction with EVE can decrease the PACU recovery time for short obstetric procedures while still providing an adequate surgical block.

Study Oversight

Has Oversight DMC: True
Is a FDA Regulated Drug?: True
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: True
Is an FDA AA801 Violation?: