Viewing Study NCT01993303


Ignite Creation Date: 2025-12-24 @ 7:32 PM
Ignite Modification Date: 2025-12-30 @ 10:48 AM
Study NCT ID: NCT01993303
Status: COMPLETED
Last Update Posted: 2013-11-25
First Post: 2012-08-01
Is Gene Therapy: True
Has Adverse Events: False

Brief Title: Direct Comparison of 2D Cardiac PET With 3D Cardiac PET
Sponsor: Cardiovascular Imaging Technologies
Organization:

Study Overview

Official Title: Direct Comparison of 2D Cardiac PET With 3D Cardiac PET Using a 3D Monte-Carlo Scatter COrrection Algorithm
Status: COMPLETED
Status Verified Date: 2013-11
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: Lowering the per-infusion dose of Rb-82 offers advantages of lessening radiation exposure and extending useable generator life. Prior studies have not shown equivalence of 3D vs 2D Rb-82 PET. The investigators therefore compare 3D PET after a lower Rb-82 dose (\~20 mCi) processed using a Monte-Carlo driven scatter correction algorithm against conventional higher dosage (\~50 mCi) 2D Rb-82 PET MPI.
Detailed Description: This study re-examines 2D an 3D myocardial perfusion PET data from 19 subjects, mean age 65 years, mean BMI 30 kg/m2, 79% male. Rest and stress scans were acquired on a Siemens Accel™ PET scanner in 2D (septa extended) and 3D (septa retracted) modes. Rb-82 doses were rest 53+/-5 mCi and stress 53+/-6 mCi. Imaging times were 2D emission scan for 3 mins (90 sec delay post Rb-82 infusion), followed by a 3 minute, 3D gated emission scan (180 sec delay). Decay and shorter acquisition times led to a 62% reduction in the effective dosage 2D vs 3D datasets. 3D images were first pre-processed using a Monte-Carlo scatter and prompt gamma correction algorithm (Imagen3D™) then reconstructed using ImagenProTM (CVIT, Kansas City, MO). Reconstructed images were evaluated using relative, 17 segment raw scores (Cedars QPET). Studies were read by consensus of 2-blinded readers for: image quality (1-4, poor-excellent), interpretive certainty (1-3, low-high) and rest perfusion using a 17 segment model (0=normal; 1-3 = mild, moderate, or severe perfusion defects). Stress segmental scores were not evaluated due to differences in imaging start time post dipyridamole infusion.

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: