Viewing Study NCT06216405



Ignite Creation Date: 2024-05-06 @ 7:59 PM
Last Modification Date: 2024-10-26 @ 3:18 PM
Study NCT ID: NCT06216405
Status: COMPLETED
Last Update Posted: 2024-01-23
First Post: 2024-01-11

Brief Title: Performance of Artificial Intelligence in Colonoscopy for Right Colon Polyp Detection
Sponsor: Groupe Hospitalier Diaconesses Croix Saint-Simon
Organization: Groupe Hospitalier Diaconesses Croix Saint-Simon

Study Overview

Official Title: Performance of Artificial Intelligence in Colonoscopy for Right Colon Polyp Detection a Randomized Controlled Trial
Status: COMPLETED
Status Verified Date: 2023-03
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: AIRCOP
Brief Summary: The aim of the study is to assess whether the use of artificial intelligence improves polyp detection in a segment of the colon the right colon

To achieve this objective patients will be divided into two groups one will undergo a standard colonoscopy the other a colonoscopy with the artificial intelligence software connected to the machine

This software does not modify the colonoscopy technique in any way and does not require the administration of any product to the patient

The study will compare the detection rate of right colon polyps between the group of patients who underwent standard colonoscopy and those who underwent colonoscopy with artificial intelligence If this number does not differ between the two groups the investigators can conclude that there is no point in using artificial intelligence
Detailed Description: Colorectal cancer CRC is the third most common cancer and remains one of the leading causes of mortality among neoplastic diseases in the world Screening colonoscopy with detection and resection of colorectal polyps have reduced CRC incidence and mortality

Nevertheless colonoscopy is an imperfect screening test and its effectiveness is influenced by a range of variables including the skill and expertise of the endoscopist Indeed a significant proportion of colorectal neoplasia is missed during colonoscopic examinations In the majority of studies the rate of interval CRC among all CRCs ranged from 2 to 9 and interval cancers occurred more likely in the right colon Interval cancers can result from missed lesion incomplete removal or newly developed cancer Most missed polyps are smaller than 10 mm in diameter and are sessile or flat in appearance Therefore sessile serrated adenomas SSAs which predominantly occur in the right colon are easily missed because they are small and sessile

Colonoscopy is less effective in screening right sided CRCs mainly because of the increased miss rate for polyps with sessile or flat appearance In recent years artificial intelligence AI is increasingly applied in gastrointestinal endoscopy especially in the detection of colorectal polyps In 2019 the first prospective randomized controlled trial including 1058 patients and comparing the polyp detection rate in colonoscopy with or without AI showed a significantly higher detection rate in the group with AI 291 vs 203 Other previous prospective studies have showed that AI had great potential for improving colonic polyp detection

To our knowledge this is the first study to date to evaluate the performance of the AI in the detection of right colon polyps

In this study the investigators aim first of all to compare the rate of right colon polyp detection with AI-aided colonoscopy AIC to the rate obtained by the Standard high-definition colonoscopy SC in patient undergoing diagnostic colonoscopy Then the investigators would to evaluate the following endpoints

1 Comparison of time required for AIC versus SC withdrawal time
2 Comparison of histological classification of all polyps detected in each group
3 Comparison of the number of right colon polyps detected in each group
4 A subgroup analysis comparing the rate of colon polyp detection between the two groups will be realized according to the procedure starting time accounting for operator fatigability

Study Oversight

Has Oversight DMC: None
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: None