Viewing Study NCT06290414



Ignite Creation Date: 2024-05-06 @ 8:12 PM
Last Modification Date: 2024-10-26 @ 3:22 PM
Study NCT ID: NCT06290414
Status: RECRUITING
Last Update Posted: 2024-03-04
First Post: 2024-02-25

Brief Title: The Accuracy of Infrared Thermographic Imaging for Assessment of Periodontal Status
Sponsor: Ain Shams University
Organization: Ain Shams University

Study Overview

Official Title: The Accuracy of Infrared Thermographic Imaging for Assessment of Periodontal Status A Cross-Sectional Study
Status: RECRUITING
Status Verified Date: 2024-08
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: The diagnosis and differentiation between periodontal diseases are currently based on the measuring and interpretation of full-mouth clinical and radiographic criteria Thermography is a modern non-invasive imaging method in which the infrared radiation emitted by an object allows the mapping and analysis of the exact temperature distribution on the surface of the object The produced thermal images correlate with variations in local blood supply and tissue metabolism Thus suggested to be a useful rapid and non-invasive tool for the diagnosis of periodontal diseases However the validity of this tool compared to standard tools should be evaluated
Detailed Description: A total of 45 of consecutive patients attending the periodontology outpatient clinic will be examined using standard periodontal clinical parameters including Plaque index PI Gingival index GI Probing depth PD Clinical attachment level CAL and standardized periapical radiograph to identify patients with gingivitis periodontitis or healthy periodontium these 45 patients will be clustered into 3 clusters consisting of 15 patients each to represent each category The same patients will be examined using an infrared thermal camera Fluke PTi120 Pocket Thermal Imager the settings will be all according to the standards of infrared medical diagnosis then the acquired images will be analyzed with Fluke SmartView IR Analysis Reporting Software and Mobile Application The images will be interpreted to detect the temperature changes in each mm in tissues in order to determine the patients with gingivitis periodontitis or healthy periodontium by an investigator blinded to clinical diagnosis Then the diagnostic sensitivity and specificity of thermographic images for diagnosis of periodontal diseases will be calculated

Study Oversight

Has Oversight DMC: None
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: None