Viewing Study NCT00615303


Ignite Creation Date: 2025-12-24 @ 7:39 PM
Ignite Modification Date: 2026-01-05 @ 4:59 AM
Study NCT ID: NCT00615303
Status: COMPLETED
Last Update Posted: 2013-02-22
First Post: 2008-02-01
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: The Effectiveness of Simethicone In Improving Visibility During Colonoscopy
Sponsor: Ramathibodi Hospital
Organization:

Study Overview

Official Title: The Effectiveness of Simethicone In Improving Visibility During Colonoscopy: A Randomized, Placebo-controlled Study
Status: COMPLETED
Status Verified Date: 2013-02
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: Sodium phosphate is one of the bowel preparation regimens for colonoscopy. However, intraluminal gas can impair visibility during the examination. Simethicone is medication that works by reducing the surface tension of air bubbles. We aimed to evaluate the effect of simethicone in enhancing visibility and efficacy during colonoscopy.
Detailed Description: A prospective, randomized, double-blinded, placebo-controlled study was conducted. One hundred and twenty-four patients were allocated to receive 2 dosages of either 45 ml of sodium phosphate plus 240 mg of simethicone tablets or 45 ml of sodium phosphate plus placebo in the evening before and in the morning of the procedure day. The colonoscopic examination was recorded. Visibility was blindly assessed for the amount of air bubbles and the degree of haziness by a single investigator. Five areas of the colon were graded for the amount of air bubbles, from 0 to 3; grade 0 and 1 were defined as the diminishing of air bubbles. The haziness was graded into 5 levels from excellent to unacceptable. Excellent, good and adequate were defined as the diminishing of haziness. The total duration of colonoscopy, the side effect of medication and the endoscopist and patient satisfaction were compared between 2 groups. Endoscopist satisfaction was evaluated by questionnaires. Visual analog scale (0-10) was used for rating patient satisfaction and the side effect of medication.

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?:

Secondary ID Infos

Secondary ID Type Domain Link View
ID12-49-23 OTHER_GRANT Gastroenterological Association of Thailand View