Viewing Study NCT06401187



Ignite Creation Date: 2024-05-11 @ 8:30 AM
Last Modification Date: 2024-10-26 @ 3:28 PM
Study NCT ID: NCT06401187
Status: COMPLETED
Last Update Posted: 2024-05-16
First Post: 2024-04-30

Brief Title: Patient Satisfaction and Maximum Biting Force in Co-Cr Bar Implant Overdenture
Sponsor: Minia University
Organization: Minia University

Study Overview

Official Title: Evaluation of Patient Satisfaction and Maximum Biting Force of Three Different Constructed Bars in Implant Overdenture in One Year Follow-up
Status: COMPLETED
Status Verified Date: 2024-04
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: bar
Brief Summary: Statement of problem Patient satisfaction and maximum biting force from patients who wear 2-implant-retained overdentures with different constructed bar attachments can be improved

Purpose This randomised controlled clinical trial assessed patient satisfaction and maximum biting force with three differently constructed bar-retained overdentures conventional casting Milling and 3D printing CADCAM techniques within a one-year follow-up

Material and methods A total of 60 implants were placed in 30 mandibular jaws30 participants The jaws were randomly assigned to 1 of the 3 treatment groups a 10 conventional technique cast Co-Cr bar attachment a 10 Co-Cr CADCAM milled bar attachment and a 10 Co-Cr CADCAM 3D-printed bar attachment all groups were connected to 2 implants in the canine area Patient satisfaction was tested after 6 months and 12 months for each group the results were collected tabulated and statistically analysed using a Pair-wise comparisons test and the Kruskal-Wallis test Maximum biting force was tested at baseline3 months 6 months and 12 months for each group the results were collected tabulated and statistically analysed using a Pair-wise comparisons test and ANOVA test
Detailed Description: A total of 60 implants were placed in 30 mandibular jaws30 participants The jaws were randomly assigned to 1 of the 3 treatment groups a 10 conventional technique cast Co-Cr bar attachment a 10 Co-Cr CADCAM milled bar attachment and a 10 Co-Cr CADCAM 3D-printed bar attachment all groups were connected to 2 implants in the canine area Patient satisfaction was tested after 6 months and 12 months for each group the results were collected tabulated and statistically analysed using a Pair-wise comparisons test and the Kruskal-Wallis test Maximum biting force was tested at baseline3 months 6 months and 12 months for each group the results were collected tabulated and statistically analysed using a Pair-wise comparisons test and ANOVA test

Study Oversight

Has Oversight DMC: None
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: None
Secondary IDs
Secondary ID Type Domain Link
Amr Esmail OTHER None None
shaimaa Radwan OTHER Minia UNiversity None