Brief Title: Contactless Assessment of Patient Vital Signs for Triage Using Remote Photoplethysmography in the Emergency Department
Sponsor: None
Organization: None

Study Overview

Official Title: Contactless Assessment of Patient Vital Signs for Triage Using Remote Photoplethysmography in the Emergency Department - 1 Observational Study CAPTURE-1 Study
Status: NOT_YET_RECRUITING
Status Verified Date: 2024-07
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: No
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: CAPTURE-1
Brief Summary: Remote photoplethysmography rPPG is a camera-based method that enables contactless measurement of variation in light absorbance by haemoglobin as reflected by the changes in skin colourpixel intensity unperceivable by human eyes Beat-to-beat variation of light-absorbance can be used to estimate the change in the arterial blood volume underneath the skin and different vital signs including the blood pressure heart rate respiratory rate and oxygen saturation SpO2 of the patient

The investigators propose an observational prospective study to independently evaluate the accuracy of contactless vital sign measurements using a cell phone-based remote photoplethysmography rPPG technology This study will recruit adult patients presenting to the Accident and Emergency Department AE of Queen Mary Hospital QMH between 1 August 2024 and 30 October 2024 The study will be divided into 2 stages In the initial run-in period the investigators will collect facial video data from 200 patients to calibrate the VitalsTM system in the AE environment Then the investigators will evaluate the accuracy of the VitalsTM in estimating vital signs of 1000 ambulatory patients in the AE setting

A trained research nurse and research assistant will be deployed from 0900 to 1700 on weekdays to screen for eligible patients in the AE waiting hall and to recruit patient participants throughout the study period In this study the investigators will only recruit triage category 3 semi-urgent to 5 non-urgent patients who are clinically stable and evaluate the performance of the VitalsTM in a designated room in AE Written informed consent will be obtained from all patient participants after an explanation of the details of the study including the rationale benefits and risks of participation

After informed consent contactless and manual measurement of patient blood pressure heart rate respiratory rate body temperature and SpO2 will be carried out simultaneously in a designated room in AE A mounted light emitting diode LED will be used as the light source Facial video of the patient participant will be captured using an iPhone an iPad and a thermal camera placed at around 50 cm from the patient A reference object for thermal and visual imaging will be placed at the background Also ambient temperature and light intensity will be measured

The patient will be asked to sit down and remain still during video-recording Manual measurement will be performed simultaneously by a trained research nurse or research assistant using standard hospital device or other medical-grade devices A software program will be used to log vital sign measurements and recordings simultaneously so that data can be synchronised to reduce variations

The primary outcome is the accuracy of the VitalsTM platform in estimating patient heart rate measured in intraclass correlation coefficient ICC The investigators will also measure of accuracy of the VitalsTM platform in estimating other vital signs including blood pressure respiratory rate SpO2 and body temperature The investigators will also evaluate patient satisfaction and comfort with the contactless and manual measurement techniques

The accuracy of contactless measurement will be determined by calculating the ICC from the manual measurement readings as the ground truths The investigators will also calculate the root mean square error RMSE and Pearson correlation between the contactless and manual measurement readings for individual vital signs Altman Bland plot will be used to evaluate the bias and limits of agreement between two vital sign measurement methods