Viewing Study NCT06507319



Ignite Creation Date: 2024-10-26 @ 3:35 PM
Last Modification Date: 2024-10-26 @ 3:35 PM
Study NCT ID: NCT06507319
Status: RECRUITING
Last Update Posted: None
First Post: 2024-07-02

Brief Title: Comparative Evaluation Of Two Bone-Anchored Maxillary Molar Distalization Appliances Direct Versus Indirect Anchorage
Sponsor: None
Organization: None

Study Overview

Official Title: Comparative Evaluation Of Two Bone-Anchored Maxillary Molar Distalization Appliances Direct Versus Indirect Anchorage
Status: RECRUITING
Status Verified Date: 2024-07
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: No
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: Aim of study this study will be conducted for Comparative Evaluation Of Two Bone-Anchored Maxillary Molar Distalization Appliances Direct Versus Indirect Anchorage

Material and methods The study will consist of two groups each group has 10 Patients The patients will be selected from the outpatient clinic of the orthodontic department at Mansoura University

Patients will be divided into 2 groups group 1 will be treated by direct bone anchored pull distal slider and group 2 by indirect bone anchored dual force distalizer
Detailed Description: Aim of study

this study will be conducted for Comparative Evaluation Of Two Bone-Anchored Maxillary Molar Distalization Appliances Direct Versus Indirect Anchorage

Participant and eligibility criteria

The study will consist of two groups each group has 10 Patients The patients will be selected from the outpatient clinic of the orthodontic department at Mansoura University pretreatment records will be taken including intraoral and extraoral photographs study models panoramic radiographs and lateral cephalometric radiographs

Intervention

written and informed consents will be taken from the patients

Group 1

Two metal bands will be chosen and fitted on the maxillary first molars
Rubber base impression material will be taken with bands in place
Two metal bands will be placed in their relative positions in the impression and then poured up with stone
Send it to the LAB for appliance fabrication
At delivery day the appliance will be cemented on the maxillary first molars by glass ionomer luting cement and two miniscrews will be placed in their positions
The appliance will be activated by closed coil spring which apply 300g force Patients will be monitored every 3 weeks

Group 2

Four metal bands two for maxillary first premolars and two for maxillary first molars will be chosen and fitted on the teeth
Rubber base impression material will be taken with bands in place
Four metal bands will be placed in their relative positions in the impression and then poured up with stone
Send it to the LAB for appliance fabrication
At delivery day the appliance will be cemented on the teeth by glass ionomer luting cement and two miniscrews will be placed in their positions and activated by compressing the NiTi open coil spring which apply 300g force Patients will be monitored every 3 weeks

Study Oversight

Has Oversight DMC: None
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: None