Viewing Study NCT03185832


Ignite Creation Date: 2025-12-24 @ 9:26 PM
Ignite Modification Date: 2025-12-25 @ 7:11 PM
Study NCT ID: NCT03185832
Status: COMPLETED
Last Update Posted: 2022-02-14
First Post: 2017-06-12
Is NOT Gene Therapy: False
Has Adverse Events: True

Brief Title: Heart Failure and Sudden Cardiac Death Japan Registry
Sponsor: Boston Scientific Corporation
Organization:

Study Overview

Official Title: Heart Failure Indication and Sudden Cardiac Death Prevention Trial Japan
Status: COMPLETED
Status Verified Date: 2022-02
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: HINODE
Brief Summary: The purpose of this observational registry is to collect clinical events and outcome data in 4 different study populations (cohorts), with a majority of Japanese subjects, that are at risk of sudden cardiac death (SCD) and heart failure (HF) events. These event rates will be compared with available published data mainly from Europe and the United States.

Selected Subject Cohorts:

1. Selected subject cohort with criteria for SCD (without spontaneous prior ventricular sustained arrhythmia) and de novo Implantable Cardioverter-Defibrillator (ICD) device treatment.
2. Selected subject cohort with criteria for SCD and widely accepted standard cardiac resynchronization therapy (CRT) indication who received a de novo CRT-Defibrillator (CRT-D) device treatment.
3. Selected subject cohort who are clinically expected to require \>40% right ventricular pacing with a left ventricular ejection fraction (LVEF) ≤50%, any determined New York Heart Association (NYHA) Class, and receiving pacemaker (PM) or CRT-Pacemaker (CRT-P) therapy despite previous device history (de novo, box changes, system revisions or upgrades).
4. Selected subject cohort with criteria for SCD fulfilling European Society of Cardiology (ESC) ICD or CRT-D therapy guidelines (2016) with an LVEF ≤35%, having 2 to 5 predefined SCD risk factors but do not have or had have a cardiac implanted defibrillator, CRT-D, PM, or CRT-P.

The primary endpoint will report on the Composite rate of first appropriately treated ventricular arrhythmia (by anti-tachycardia pacing \[ATP\] or shock) or life-threatening symptoms associated to ventricular arrhythmia (defined as hemodynamic instability which requires treatment), whichever comes first under MADIT RIT Arm B or C programming conditions in a study population with a majority of Japanese subjects. This primary end point is assessed in the ICD/CRT-D implanted patient cohort.

The all-cause mortality in subjects with a maximum of 3 risk factors (analyzed for MADIT II data) will be assessed in the Pacing (PM/CRT-P) patient cohort.

The all-cause mortality will be assessed in the non-implanted subject cohort.
Detailed Description: None

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: True
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: True
Is an FDA AA801 Violation?: