Viewing Study NCT02492932


Ignite Creation Date: 2025-12-24 @ 9:40 PM
Ignite Modification Date: 2026-01-01 @ 8:00 AM
Study NCT ID: NCT02492932
Status: NOT_YET_RECRUITING
Last Update Posted: 2023-12-01
First Post: 2015-06-09
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: The Second Try During Landmark Approach of the Internal Jugular Vein: an Ultrasonographic Prelocation Study
Sponsor: Seoul National University Hospital
Organization:

Study Overview

Official Title: The Second Try During Landmark Approach of the Internal Jugular Vein: an Ultrasonographic Prelocation Study
Status: NOT_YET_RECRUITING
Status Verified Date: 2023-11
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: Two approaches are possible when the first finder needle attempt of the internal jugular vein cannulation fails; the needle can be turned slightly laterally or the puncture point can be moved slightly medially. This study is an ultrasonographic stimulation study to evaluate the success rate of turning the needle laterally and moving the puncture point medially, and to determine the proper angle or distance for the second try of internal jugular vein cannulation.
Detailed Description: Immediately after induction of general anesthesia, the patient's head is turned slightly, and the table is tilted at 10 degrees, and the puncture point estimated by the anatomical landmarks are marked on the patient's skin. The investigators obtain a sonographic view at the estimated puncture point. It is recorded "success" when the internal jugular vein is visualized on the ultrasonography, and the estimated needle path passes the internal jugular vein. It is recorded "failure" if the internal jugular vein is not visualized on the ultrasonography, and the estimated needle path does not pass the internal jugular vein. After "failure" of the first attempt, the probe is either turned laterally or moved medially until the internal jugular vein is visualized on the ultrasonography, and the estimated needle path passes the internal jugular vein. The angle and distance is recorded. The location of the carotid artery is always marked on the ultrasonography for evaluation of complications.

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: