Viewing Study NCT02518269


Ignite Creation Date: 2025-12-24 @ 10:47 PM
Ignite Modification Date: 2026-01-01 @ 9:32 AM
Study NCT ID: NCT02518269
Status: ACTIVE_NOT_RECRUITING
Last Update Posted: 2025-11-25
First Post: 2015-04-29
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: A 3-Arm Study on G7 Acetabular Cup With Echo BiMetric Stem in Total Hip Arthroplasty
Sponsor: Zimmer Biomet
Organization:

Study Overview

Official Title: A Prospective 3-Arm Randomized Controlled Study on G7 Acetabular Cup With Echo BiMetric Stem in Total Hip Arthroplasty
Status: ACTIVE_NOT_RECRUITING
Status Verified Date: 2025-11
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: The study is designed to compare three articulation options in terms of osteolysis, patient satisfaction, clinical and radiographic outcomes (Oxford Hip score (OHS) and Harris Hip score (HHS) and safety.

In addition, the purpose of the study is also to evaluate the safety and effectiveness of patients who received G7 Acetabular system in conjunction with Echo BiMetric stem in primary total hip arthroplasty.
Detailed Description: DESIGN: Prospective 3 Arm Randomized controlled trial.

PURPOSE:To compare three commonly used contemporary bearings in Total Hip Arthroplasty (THA). In addition, to evaluate the safety and effectiveness of the G7 Cups and Echo BiMetric Stem in THA.

OUTCOME MEASURES: Osteolysis, clinical outcomes, patient satisfaction, intraoperative/surgical data, implant positioning, survivor ship, and adverse events.

POPULATION: 360 hips (240 will have CT scan for analysis of osteolysis).

ELIGIBILITY: Patients who meet inclusion and exclusion criteria defined in this protocol.

DURATION: All patients will be followed at 3 months, 1, 2, 5, 7 and 10 year postoperatively. Assuming the enrollment will be completed 18 months. The total study duration will be 11.5 years.

STUDY GROUPS/TREATMENTS

Group 1 - G7 Metal-on-Polyethylene (MoP) (Arcom XL) + Echo BiMetric Group 2 - G7 Metal-on-Polyethylene (MoP) (E1) + Echo BiMetric Group 3 - G7 Ceramic-on-Ceramic (CoC) + Echo BiMetric The study's primary efficacy endpoint will include the difference in osteolytic volume at 5 years postoperatively measured by Computertomografi (CT) scan.

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: