Viewing Study NCT04569669


Ignite Creation Date: 2025-12-24 @ 11:14 PM
Ignite Modification Date: 2025-12-25 @ 8:49 PM
Study NCT ID: NCT04569669
Status: UNKNOWN
Last Update Posted: 2020-09-30
First Post: 2020-07-30
Is NOT Gene Therapy: False
Has Adverse Events: False

Brief Title: The Sensitivity and Specificity of CardioSimFFRct Analysis Software on Coronary Artery Stenosis
Sponsor: CCRF Inc., Beijing, China
Organization:

Study Overview

Official Title: A Clinical Trial on the Diagnostic Performance Based on CT-Derived Fractional Flow Reserve Score Analysis Software for Coronary Artery Stenosis
Status: UNKNOWN
Status Verified Date: 2020-09
Last Known Status: NOT_YET_RECRUITING
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: The device involved in this trail is a diagnostic software with a Prospective, Multicenter, Self Controlled design. FFRCT diagnostic performance was calculated by CardioSimFFRct Analysis software, and the diagnostic accuracy, sensitivity, specificity, positive predictive value and negative predictive performance of FFRCT for myocardial ischemia were calculated per-patient level and per-vessel level with invasive FFR value as gold standard.
Detailed Description: The present study is a single arm, open label, prospective trial. Measurement of FFR during invasive cardiac catheterization represents the "gold standard" for assessment of the hemodynamic significance of coronary artery lesions. As we know, the major disadvantage of FFR is that it has to be measured invasively. CardioSimFFRct Analysis software is a non-invasive method to determine FFR which computes the hemodynamic significance of Coronary Artery Disease (FFRCT) from coronary computed tomography angiography(CCTA)data of the subject by using computational fluid dynamics.The FFR derived from FFR-CT will be compared with invasive FFR as gold standard.Moreover CardioSimFFRct also simplifies the coronary artery into a one-dimensional piping model, omits grid engineering, and greatly reduces the complexity of pretreatment.Based on the pressure loss along the pipe flow and the local pressure loss, a fast method for FFR calculation in engineering is proposed. The calculation time can be reduced to several minutes.

FFRct from CardioSimFFRct Analysis software is mainly based on CCTA images to image the coronary arteries. Through three-dimensional reconstruction of the coronary arteries and computational fluid Dynamics (CFD) technology, the simulation of blood flow in the blood vessels is realized to extract the coronary blood flow reserve score (FFR).FFRct has the following characteristics such as the FFR value can be measured noninvasively, without additional damage to patients, avoiding the risks brought by invasive surgery, and the side effects brought by drugs during invasive surgery.FFRct can realize the examination quickly, save the time of doctors' coronary functional assessment, and simplify the process of coronary functional assessment.It also has the function of three-dimensional reconstruction of blood vessels, which makes it convenient for users to view the whole structure of coronary arteries and make artificial correction.The results of FFRct have high repeatability and are easy for users to evaluate.

Study Oversight

Has Oversight DMC: True
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: