Viewing Study NCT02425956


Ignite Creation Date: 2025-12-24 @ 11:24 PM
Ignite Modification Date: 2026-01-04 @ 6:17 PM
Study NCT ID: NCT02425956
Status: COMPLETED
Last Update Posted: 2017-07-24
First Post: 2015-03-16
Is NOT Gene Therapy: True
Has Adverse Events: True

Brief Title: Non-invasive Quantification of Liver Iron With MRI
Sponsor: GE Healthcare
Organization:

Study Overview

Official Title: Non-invasive Quantification of Liver Iron With MRI
Status: COMPLETED
Status Verified Date: 2017-06
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: This study is being conducted to build a library of prospectively collected clinical data from subjects with iron overload examined with commercially available MRI devices. This data library is intended for use in future engineering development and other research activities, including future regulatory submissions.
Detailed Description: This study is being conducted to build a library of prospectively collected clinical data from subjects with iron overload examined with commercially available MRI devices. This data library is intended for use in future engineering development and other research activities, including future regulatory submissions. Data from human subjects is required to develop and test Magnetic resonance (MR) reconstruction techniques that can provide quantitative information about tissue properties, such as volumetric fat and iron concentrations. Collection of MR data and corresponding quantitative liver iron concentration (LIC) data is necessary for development of MR techniques that can show both overall and regional iron concentrations of in vivo tissues. These techniques may provide viable alternatives to invasive and expensive conventional liver biopsy and to less accurate serum biomarker testing, potentially benefiting future clinical patients with iron overload.

MR image data and corresponding quantitative data about serum and liver iron levels will be collected from each subject in this study. These datasets are considered suitable for future development and testing of MR reconstruction software, including MR reconstruction algorithms developed by General Electric Healthcare (GEHC) to use Longitudinal relaxation rate equal to the reciprocal of T2 relaxation time (1/T2) (R2) techniques to assess LIC. To achieve a sufficiently diverse library for future testing, MRI data of the liver and surrounding tissues will be acquired using 1.5T and 3.0T GEHC IDEAL IQ scans and commercially available 1.5T MRI scans conducted according to the FerriScanĀ® Specialized Reconstruction Service guidelines (Resonance Health, Claremont, AU). Quantitative hematologic (serum ferritin) based on blood testing and FerriScanĀ® Analysis Service LIC reports will be collected for each subject.

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: