Viewing Study NCT00665756


Ignite Creation Date: 2025-12-24 @ 11:28 PM
Ignite Modification Date: 2025-12-30 @ 6:41 PM
Study NCT ID: NCT00665756
Status: UNKNOWN
Last Update Posted: 2008-04-24
First Post: 2008-04-23
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: Comparison of Efficacy Between Silicone Ahmed Glaucoma Valves and Second Trabeculectomy in Glaucoma Patients
Sponsor: Federal University of São Paulo
Organization:

Study Overview

Official Title: Comparison of Efficacy Between Silicone Ahmed Glaucoma Valves and Second Trabeculectomy in Glaucoma Patients
Status: UNKNOWN
Status Verified Date: 2008-04
Last Known Status: ACTIVE_NOT_RECRUITING
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: In the management of open angle glaucoma, frequently more then one procedure is necessary to control the intra ocular pressure. There is still no consensus whether this second intervention should be a second trabeculectomy or a shunt device. In the present study we compare a second trabeculectomy versus Ahmed silicone shunt device in open angle glaucoma patients with previous trabeculectomy without proper IOP control.
Detailed Description: In the management of open angle glaucoma, frequently more then one procedure is necessary to control the intra ocular pressure. There is still no consensus whether this second intervention should be a second trabeculectomy or a shunt device. In the present study we compare a second trabeculectomy versus Ahmed silicone shunt device in open angle glaucoma patients with previous trabeculectomy without proper IOP control.

40 Patients with clinically uncontrolled open angle glaucoma with previous trabeculectomy surgery were selected from the glaucoma sector of Federal university of Sao Paulo. Patients were randomized to one of two groups:

1. Silicone Ahmed Implant
2. Second trabeculectomy

Surgery description:

Ahmed silicone tube implant: A fornix-based conjunctival flap was created between two adjacent recti muscles. Before placement of the tube implant body to the sclera, tube was irrigated with saline solution to open the valve mechanism. The implant's polypropylene body was sutured to sclera with 6.0 silk suture. The tube then trimmed and the anterior chamber was entered from 1mm posterior to corneoscleral limbus with 23-gauge needle. A human donor scleral flap was placed over the tube and sutured to the sclera with 10.0 nylon suture. The conjunctiva was sutured to the limbus.

Second Trabeculectomy: A fornix-based conjunctival flap was created in the opposite superior quadrant of the previous trabeculectomy. Mitomycin-C was used under the conjunctival flap for up to 4 minutes (0,3mg/mL) and rinsed with 30mL saline solution. Scleral flap with crescent bevel and sclerectomy with a punch. Iridectomy and flap suture with nylon 10-0. Conjunctival suture with nylon 10-0.

Follow up after surgery was in the 1st, 4th, 7th, 15th, 30th days and after that monthly or whenever needed for clinical reasons.

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: