Viewing Study NCT03175406


Ignite Creation Date: 2025-12-26 @ 2:39 PM
Ignite Modification Date: 2026-01-01 @ 12:21 AM
Study NCT ID: NCT03175406
Status: COMPLETED
Last Update Posted: 2017-06-05
First Post: 2017-05-28
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: Predicting the Outcomes of Labor Induction
Sponsor: Ain Shams University
Organization:

Study Overview

Official Title: Comparing the Accuracy of Manipal Cervical Scoring System and Modified Bishop Score in Predicting Successful Induction of Labor
Status: COMPLETED
Status Verified Date: 2017-05
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: Pre induction assessment using bishop scoring system and Manipal cervical scoring system performed on 105 pregnant females
Detailed Description: preinduction cervical assessment using The Burnett modification of Bishop score with

1. Cervical dilatation in centimeters will be given a score of zero if dilatation less than 1cm, a score of 1 if 1-2 cm dilated, a score of 2 if more than 2 cm dilataion.
2. Length of the cervix will be given a score of zero if more than 2 cm, a score of 1 if 1-2 cm, a score of 2 if less than 1 cm.
3. Station of fetal head will be given a score of zero if -2 or higher , a score of 1 if -1, a score of 2 if zero or lower.
4. Consistency of the cervix will be given a score of zero if firm, a score of 1 if soft and a score of 2 if soft and stretchable.
5. Position of the cervix will be given a score of zero if posterior, a score of 1 if mid position and a score of 2 if anterior. So, a total score (sum of all scores) of zero at a minimum to 10 at a maximum can be estimated.

and also preinduction cervical assessment using transvaginal ultrasound and Manipal system where:

1. Length of the cervix will be given a score of zero if more than 3 cm, a score of 1 if 2-3 cm, a score of 2 if less than 2 cm.
2. Length of the funnel will be given a score of zero if absent, a score of 1 if ≤ 0.5 cm, a score of 2 if more than 0.5 cm.
3. width of the funnel will be given a score of zero if absent, a score of 1 if ≤ 0.5 cm, a score of 2 if more than 0.5 cm.
4. cervical position and shape will be given a score of zero if curved, a score of 2 if straight
5. Distance of presenting part to external os will be given a score of zero if more than 3 cm, a score of 1 if 2-3 cm, a score of 2 if less than 2 cm

Study Oversight

Has Oversight DMC: None
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: