Viewing Study NCT03191851


Ignite Creation Date: 2025-12-24 @ 11:42 PM
Ignite Modification Date: 2025-12-25 @ 9:33 PM
Study NCT ID: NCT03191851
Status: COMPLETED
Last Update Posted: 2020-11-19
First Post: 2016-12-01
Is NOT Gene Therapy: False
Has Adverse Events: False

Brief Title: Evaluation of 'Melody' Paracentesis Device for Ascites Therapy
Sponsor: University of Nottingham
Organization:

Study Overview

Official Title: Evaluation of 'Melody' Paracentesis Device for Ascites Therapy in Patients With Cirrhosis (EMPATHY)
Status: COMPLETED
Status Verified Date: 2020-11
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: EMPATHY
Brief Summary: Ascites is the accumulation of fluid inside the abdomen. This can happen when the liver fails due to a substantial amount of scarring (cirrhosis). Patients (pts) must have this fluid drained and as cirrhosis progresses, patients will require drainage of ascites repeatedly on a regular basis, leading to frequent hospitals visits and increased complications.

The current drainage device is slow and doesn't always drain completely so pts have to return repeatedly to keep symptoms under control.

A new device (called Melody) has been developed and specifically designed for the purpose of draining ascites fluid, which the Investigators expect to drain faster and completely.

This study will compare the volume of ascites drained using the new 'Melody' catheter device with that used in standard NHS practice. If the melody catheter device is confirmed as superior to the current device this would improve patient experience (less frequent visits to hospital and increased length of time between visits).

With fewer procedures performed per patient, the pressure on the NHS would be greatly reduced in terms of time and costs.
Detailed Description: Large volume paracentesis has been established as a treatment for symptomatic ascites and is performed regularly in secondary care hospitals widely across the UK.

Lack of a device specifically designed to perform paracentesis means that flow of ascites fluid through the catheter is not optimal leading to incomplete drainage and hence, frequent repeated paracentesis as well as a number of complications.

A new 'Melody' catheter device has been designed and developed in collaboration with Mediplus Ltd and NIHR Enteric Bowel function Healthcare Technology Co-operative; specifically designed to improve the performance characteristics of paracentesis procedure.

(The 'Melody ascites drainage catheter' including 'sterile ascetic drainage sets' is CE marked for clinical use). In addition, investigators would also like to confirm whether the addition of a pump will improve drainage with this device further.

The Investigators propose to carry out a feasibility study, 'EMPATHY', with an aim to compare the performance characteristics of 'Melody' catheter device (with and without addition of 'Andromeda' pump) with the current device. 112 patients with ascites requiring therapeutic paracentesis will be randomised to undergo the procedure using one of the two devices. The volume of ascites drained per session will be compared along with ease of insertion and removal as well as patient experience including all adverse events up to 7 days following the procedure. The outcomes of this feasibility study will inform further refinement of the 'Melody' catheter device as well as a future large multi-centre randomised controlled trial evaluating the cost-effectiveness of the new 'Melody' catheter device in therapeutic paracentesis

Study Oversight

Has Oversight DMC: True
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: