Viewing Study NCT02952651


Ignite Creation Date: 2025-12-24 @ 11:47 PM
Ignite Modification Date: 2025-12-31 @ 9:09 AM
Study NCT ID: NCT02952651
Status: COMPLETED
Last Update Posted: 2018-02-27
First Post: 2016-10-19
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: Prediction of Fluid Responsiveness in Children Undergoing Major Surgery
Sponsor: Seoul National University Hospital
Organization:

Study Overview

Official Title: Prediction of Fluid Responsiveness Using Respiratory Variation in Pulse Oximeter Plethysmography in Children Undergoing Major Surgery
Status: COMPLETED
Status Verified Date: 2018-02
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: The purpose of this study is to evaluate predictability of a respiratory variation in pulse oximeter plethysmography for fluid responsiveness in children undergoing major surgery.
Detailed Description: The purpose of this study is to evaluate predictability of a a respiratory variation in pulse oximeter plethysmography (delta POP) for fluid responsiveness in children undergoing major surgery.

When there are clinical signs of hypovolemia, such as hypotension, decreased urine output and central venous pressure less than 5 mmHg, the study will be started. At index fingers of both hand, pulse oximeter sensors are applied by gradually increasing the contact force (from 0 to 1.4N, being increased by 0.2-0.3N). Then, pulse oximeter plethysmography (POP) waveforms are obtained for 90 seconds. Then, intravenous crystalloid fluid 10 mL/kg is infused for 15 min.

To evaluate the change of cardiac output, transesophageal or transthoracic echocardiography is performed before and after fluid administration. In addition, hemodynamic parameters including pulse pressure variation, systolic pressure variation, pleth variability index and central venous pressure are also recorded before and after fluid administration.

Finally, patients will be divided into fluid responder group and non-responder group. If stroke volume index measured using echocardiography increases over 15% after fluid administration, the patient will be fluid responder.

Delta POP (%) obtained from each finger with different contact force is calculated as follows;(POPmax - POPmin)/{(POPmax + POPmin)/2}. Using receiver operating characteristic curve, diagnostic power of delta POPs from different contact forces for fluid responsiveness will be evaluated. In addition, difference between delta POP from low contact force and that from high contact force will be evaluated.

Study Oversight

Has Oversight DMC: True
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: