Viewing Study NCT06634251


Ignite Creation Date: 2025-12-24 @ 11:54 PM
Ignite Modification Date: 2025-12-25 @ 9:50 PM
Study NCT ID: NCT06634251
Status: COMPLETED
Last Update Posted: 2024-10-09
First Post: 2024-10-08
Is NOT Gene Therapy: False
Has Adverse Events: False

Brief Title: Antegrade Screw Placement Technique in Anterior Column of Acetabulum
Sponsor: Bakirkoy Dr. Sadi Konuk Research and Training Hospital
Organization:

Study Overview

Official Title: Defining Fluoroscopic Visualization Technique for Optimal Antegrade Entry Point and Anatomical Parameters in Anterior Column Fixation Corridor for Pelvic Surgery: A Novel Perspective
Status: COMPLETED
Status Verified Date: 2024-10
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: This retrospective observational study aims to define the optimal antegrade entry point for screw placement in the anterior column fixation corridor (ACFC) of the acetabulum. Using fluoroscopic visualization techniques, the study examines computed tomography (CT) scans from 500 healthy adult patients to simulate screw placement and measure anatomical parameters. The goal is to determine patient-specific entry points and to assess the feasibility of screw placement using axial fluoroscopic views. The study also investigates gender-specific anatomical variations to provide insights for safer and more precise screw placement during anterior column fixation in pelvic surgery.
Detailed Description: This study focuses on developing and validating a fluoroscopic visualization technique for identifying the optimal antegrade entry point (OAEP) in the anterior column fixation corridor (ACFC) of the acetabulum during pelvic surgery. Using three-dimensional reconstructions from pelvic computed tomography (CT) data of 500 healthy adults, the study simulates screw placement within the ACFC. A cylinder representing the screw is inserted virtually through the OAEP, ensuring that it remains within the confines of the fixation corridor without breaching its boundaries. The study records anatomical measurements, including the corridor's diameter, length, and the angles required for sagittal and coronal plane inclinations to visualize the OAEP.

The study also examines gender-specific anatomical variations, including differences in ACFC diameter, length, and required fluoroscopic angles. By defining patient-specific entry points and establishing a reliable fluoroscopic technique, this study aims to provide a practical and accessible method for anterior column fixation, minimizing complications and improving the safety and precision of screw placement in pelvic surgeries.

This novel approach has the potential to offer a cost-effective alternative to more expensive navigation systems, making it widely applicable in clinical settings.

Study Oversight

Has Oversight DMC: None
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: