Viewing Study NCT00304967


Ignite Creation Date: 2025-12-25 @ 12:38 AM
Ignite Modification Date: 2025-12-25 @ 10:48 PM
Study NCT ID: NCT00304967
Status: COMPLETED
Last Update Posted: 2017-07-02
First Post: 2006-03-18
Is NOT Gene Therapy: False
Has Adverse Events: False

Brief Title: Dynamic Light Scattering to Study Crystalline Proteins in Young Normal Lenses
Sponsor: National Eye Institute (NEI)
Organization:

Study Overview

Official Title: A Study of Crystalline Proteins in Young Normal Lenses Using the NASA-NEI Dynamic Light Scattering (DLS) Device
Status: COMPLETED
Status Verified Date: 2007-03-31
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: This study will use a method called dynamic light scattering (DLS) to study the lens of the eye in young normal subjects. The DLS device uses a very dim laser light to study the lens of the eye. It detects proteins in the lens, identifying early changes that may make the device useful in future cataract studies. This study will use DLS to examine the characteristics of proteins in healthy young lenses that can be used for comparison with lenses in older people and people with cataracts.

Normal volunteers aged 5 to 21 years may be eligible for this study. Participants undergo the following procedures:

Medical history

Eye examination with dilation to include:

* Measurement of visual acuity
* Examination of pupils and eye movements
* Examination of the front of the eye (cornea, lens) with a slit lamp bio-microscope
* Examination of retina with an ophthalmoscope (instrument with a strong light and magnifying lens)
* Dynamic light scattering
Detailed Description: The NASA-NEI Dynamic Light Scattering (DLS) device detects early molecular lens changes before clinical means are able to detect any lens changes in animal and limited human studies. This ability will make it very useful in future clinical studies of cataract etiology as well as treatment. A recently concluded clinical cross sectional study of lenses (in vivo) using the DLS device showed good reproducibility and good correlation with clinical cataract grading. It also detected remarkable changes in the lens crystalline proteins with aging and with cataract formation. We therefore propose to study the characteristics of the crystalline proteins in pristine young normal lenses with DLS for comparison with aging and cataractous lens findings. We will examine 30 young normal subjects, perform undilated eye examinations, and obtain DLS measurements of their lenses. We will then use these DLS measurements for comparison with the previously obtained aging and cataract DLS measurements, to obtain normative data for future lens and cataract clinical studies.

Study Oversight

Has Oversight DMC:
Is a FDA Regulated Drug?:
Is a FDA Regulated Device?:
Is an Unapproved Device?:
Is a PPSD?:
Is a US Export?:
Is an FDA AA801 Violation?:

Secondary ID Infos

Secondary ID Type Domain Link View
06-EI-0117 None None View