Viewing Study NCT06343467


Ignite Creation Date: 2025-12-25 @ 12:39 AM
Ignite Modification Date: 2025-12-25 @ 10:49 PM
Study NCT ID: NCT06343467
Status: COMPLETED
Last Update Posted: 2024-08-28
First Post: 2024-03-14
Is NOT Gene Therapy: False
Has Adverse Events: True

Brief Title: Do Generic Volar Locking Plates Provide Similar Outcomes at a Reduced Cost?
Sponsor: HealthPartners Institute
Organization:

Study Overview

Official Title: Generic Volar Locking Plate Use in Distal Radius Fractures: A Prospective Randomized Study to Evaluate Clinical Outcomes and Cost Reduction
Status: COMPLETED
Status Verified Date: 2024-03
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: Across orthopedics, the investigators will be using the generic volar locking plates for patients undergoing open reduction and internal fixation (ORIF) of the distal radius using a block schedule, meaning one month we the generic implants and one month we use conventional implants from the surgeon's brand of choice. At the end of each month the health system will switch which type of implants (generic vs. conventional) they will use at their facilities. From a quality perspective each patient will be monitored both short and long term for complication and reoperation. This will be done through chart review.
Detailed Description: Patients will be consented to surgery per a standard surgical consent form. Six surgeons who regularly perform distal radius fracture (DRF) ORIF are included (five hand and one orthopaedic trauma fellowship-trained). Per the practice protocol, patients will either be treated with a generic plate or a brand name plate as described above. Ultimately, the decision to use a generic volar locking plate (VLP) is left up to surgeon discretion. All surgical and follow-up data will be collected. Implants used, age at time of surgery, weight, height, gender, race, ethnicity, comorbidities (diabetes, heart disease, etc.), complications including, but not limited to: readmission, reoperation, non-union, wound dehiscence, and lab tests will be collected. This will be evaluated all within 90 days following surgery. Implants will be cross referenced with the institution's data base to determine cost. All data will be collected on a secure server and be kept password protected. The primary outcome was 90-day postoperative complications (readmissions, reoperations, and mortality rates) by implant vendor type (generic vs. conventional). Secondary outcomes consisted of implant costs, estimated blood loss, and tourniquet time. An a priori power analysis was conducted to estimate the minimum sample size needed to adequately detect a difference in reoperation rates with a large effect size (Cohen's d=0.8). At a Type I error rate of 0.05, a power of 80%, and a 1:1 group allocation, the estimated sample size was 36 patients (18 generic VLPs vs. 18 conventional VLPs). Statistical significance was set to p≤0.05.

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: True
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: True
Is an FDA AA801 Violation?: