Viewing Study NCT01686893


Ignite Creation Date: 2025-12-25 @ 1:22 AM
Ignite Modification Date: 2025-12-25 @ 11:31 PM
Study NCT ID: NCT01686893
Status: UNKNOWN
Last Update Posted: 2012-09-19
First Post: 2012-09-13
Is NOT Gene Therapy: False
Has Adverse Events: False

Brief Title: Evaluation of Safety and Efficacy of Shorttime TNI Treatment in Patients With COPD
Sponsor: Medical University Innsbruck
Organization:

Study Overview

Official Title: STIT-1 Evaluation of Safety and Efficacy of Shorttime TNI Treatment in Patients With COPD
Status: UNKNOWN
Status Verified Date: 2012-09
Last Known Status: RECRUITING
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: STIT-1
Brief Summary: Evaluation of Safety and Efficacy of Shorttime TNI Treatment in Patients with COPD Acute testing of oxygen demand using TNI vs. standard oxygen application in stable COPD patients An investigator-initiated, prospective, controlled, multicenter study
Detailed Description: TNI, the nasal insufflation of a high flow of warm, humidified air, is an extremely comfortable and uncomplicated alternative to numerous other approaches in non-invasive ventilation (NIV). Up to now, NIV therapy could only be applied by masks with the associated complications as patients could not tolerate high airflow delivered by a thin nasal cannula without humidification and warming, thus causing concomitant negative effects. The new therapy TNI shows a high rate of acceptance by children, too.

At present, there are two different types of devices available for nasal insufflation in clinics:

TNI 20s, an air humidifier for clinical compressed air, and the TNI20 oxy, an air humidifier for clinical compressed air, which can be combined with oxygen.

TNI 20 oxy The system, which is unique throughout the world, is optimized for the application of flows of up to 20L/min and fulfils the minimum requirements of the "American Society of Testing and Materials" for a high flow air humidifier in the non-invasive application of 10 mg H2O/L (equivalent to about 60% rel. humidity at an ambient temperature of 22°C) for the air humidity. The warming of the air flow by 5-15°C can be adjusted relative to the ambient temperature. Condensation is prevented in the nasal applicator by heating the tube as far as the nostrils. The device automatically controls humidity and temperature depending on the prevailing ambient conditions. The TNI®20s can be attached to the hospital infrastructure by means of a standard pressure regulator.

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?:

Secondary ID Infos

Secondary ID Type Domain Link View
AN 3546 OTHER Ethics Committee Innsbruck View