Viewing Study NCT01514305


Ignite Creation Date: 2025-12-25 @ 3:29 AM
Ignite Modification Date: 2026-01-09 @ 7:06 PM
Study NCT ID: NCT01514305
Status: COMPLETED
Last Update Posted: 2012-01-23
First Post: 2011-11-28
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: Observational Study to Evaluate the Effectiveness and Safety Study of the Dexcom G4™ Continuous Glucose Monitoring System
Sponsor:
Organization:

Raw JSON

{'hasResults': False, 'derivedSection': {'miscInfoModule': {'versionHolder': '2025-12-24'}, 'conditionBrowseModule': {'meshes': [{'id': 'D003920', 'term': 'Diabetes Mellitus'}], 'ancestors': [{'id': 'D044882', 'term': 'Glucose Metabolism Disorders'}, {'id': 'D008659', 'term': 'Metabolic Diseases'}, {'id': 'D009750', 'term': 'Nutritional and Metabolic Diseases'}, {'id': 'D004700', 'term': 'Endocrine System Diseases'}]}}, 'protocolSection': {'designModule': {'studyType': 'OBSERVATIONAL', 'designInfo': {'timePerspective': 'CROSS_SECTIONAL', 'observationalModel': 'COHORT'}, 'enrollmentInfo': {'type': 'ACTUAL', 'count': 21}}, 'statusModule': {'overallStatus': 'COMPLETED', 'startDateStruct': {'date': '2011-11'}, 'expandedAccessInfo': {'hasExpandedAccess': False}, 'statusVerifiedDate': '2012-01', 'completionDateStruct': {'date': '2011-12', 'type': 'ACTUAL'}, 'lastUpdateSubmitDate': '2012-01-20', 'studyFirstSubmitDate': '2011-11-28', 'studyFirstSubmitQcDate': '2012-01-20', 'lastUpdatePostDateStruct': {'date': '2012-01-23', 'type': 'ESTIMATED'}, 'studyFirstPostDateStruct': {'date': '2012-01-23', 'type': 'ESTIMATED'}, 'primaryCompletionDateStruct': {'date': '2011-12', 'type': 'ACTUAL'}}, 'outcomesModule': {'primaryOutcomes': [{'measure': 'Absolute Relative Difference (%) to Reference Standard', 'timeFrame': 'one time measure (day 1)', 'description': 'The primary objective is to characterize the System performance with respect to laboratory reference venous sample measurements. The device performance will be primarily evaluated in terms of point and rate accuracy of the G4 System in reference to YSI. The point accuracy is measured as the proportion of G4 System values that are within ±20% of YSI reference value for glucose levels \\>80 mg/dL and ±20 mg/dL at YSI glucose levels \\<80 mg/dL.'}]}, 'oversightModule': {'oversightHasDmc': False}, 'conditionsModule': {'conditions': ['Diabetes']}, 'descriptionModule': {'briefSummary': 'The purpose of this study is to evaluate the effectiveness and safety of the Dexcom G4 System when used as an adjuvant to blood glucose testing.\n\nDevice performance will be primarily evaluated in terms of the proportion of glucose values within a pre-specified range compared to reference values.\n\nSafety data of the G4 System will also be collected vis-a-vis adverse event reporting characterized by the incidence and severity of Serious Adverse Device Events, and Adverse Device Events experienced by study participants.'}, 'eligibilityModule': {'sex': 'ALL', 'stdAges': ['ADULT', 'OLDER_ADULT'], 'minimumAge': '18 Years', 'samplingMethod': 'NON_PROBABILITY_SAMPLE', 'studyPopulation': 'Subjects that fit the inclusion criteria will be chosen from the general population', 'healthyVolunteers': False, 'eligibilityCriteria': 'Inclusion Criteria:\n\n1. Age 18 years or older;\n2. Have been diagnosed with insulin-requiring diabetes\n3. Abstain from injecting insulin or wear an insulin pump insertion set within 3 inches from the sensor site during sensor wear;\n4. Insert sensors on their own and wear 2 systems simultaneously;\n5. Use only the blood glucose meter provided for all blood glucose measurements performed during sensor wear and not allow others to use this meter during the study;\n6. Participate in one in-clinic session comprising of fingersticks per hour and have blood draws for the entire in-clinic session;\n7. Have an intravenous catheter inserted for 4 blood draws per hour\n8. Willing to perform SMBG during home use with the meter provided;\n9. Refrain from the use of acetaminophen during sensor wear period and the day prior to sensor insertion;\n10. Speak, read, and write English;\n11. Willing and able to be compliant with provisions laid out in this protocol.\n\nExclusion Criteria:\n\n1. Have extensive skin changes/diseases that preclude wearing devices on normal skin (e.g., extensive psoriasis, recent burns or severe sunburn, extensive eczema, extensive scarring, extensive tattoos, dermatitis herpetiformis) at the proposed wear sites;\n2. Allergy to medical-grade adhesives;\n3. Pregnant as demonstrated by a positive pregnancy test within 72 hours of sensor insertion,\n4. Dialysis treatment;\n5. Hematocrit that is outside the range of 30-55% at screening visit;'}, 'identificationModule': {'nctId': 'NCT01514305', 'briefTitle': 'Observational Study to Evaluate the Effectiveness and Safety Study of the Dexcom G4™ Continuous Glucose Monitoring System', 'organization': {'class': 'INDUSTRY', 'fullName': 'DexCom, Inc.'}, 'officialTitle': 'Observational Study to Evaluate the Effectiveness and Safety Study of the Dexcom G4™ Continuous Glucose Monitoring System', 'orgStudyIdInfo': {'id': 'PTL900830'}}, 'armsInterventionsModule': {'armGroups': [{'label': 'Type 1 Diabetes Mellitus (TIDM)Type 2 Diabetes Mellitus (T2DM)', 'description': 'Adults that have been diagnosed with insulin-requiring diabetes and are on multiple daily injections (MDI) or Continuous Subcutaneous Insulin Infusion (CSII) insulin therapy;'}]}, 'contactsLocationsModule': {'locations': [{'zip': '83404', 'city': 'Idaho Falls', 'state': 'Idaho', 'country': 'United States', 'facility': 'Rocky Mountain Diabetes and Osteoporosis Center', 'geoPoint': {'lat': 43.46658, 'lon': -112.03414}}], 'overallOfficials': [{'name': 'David Price, MD', 'role': 'STUDY_DIRECTOR', 'affiliation': 'DexCom, Inc.'}]}, 'sponsorCollaboratorsModule': {'leadSponsor': {'name': 'DexCom, Inc.', 'class': 'INDUSTRY'}, 'responsibleParty': {'type': 'SPONSOR'}}}}