Viewing Study NCT02032420


Ignite Creation Date: 2025-12-25 @ 4:26 AM
Ignite Modification Date: 2026-01-16 @ 5:37 PM
Study NCT ID: NCT02032420
Status: COMPLETED
Last Update Posted: 2017-02-13
First Post: 2013-12-18
Is NOT Gene Therapy: True
Has Adverse Events: True

Brief Title: The Effects of the STAR Maneuver on UGRA Training
Sponsor:
Organization:

Raw JSON

{'hasResults': True, 'derivedSection': {'miscInfoModule': {'versionHolder': '2025-12-24'}}, 'resultsSection': {'moreInfoModule': {'pointOfContact': {'email': 'nlam@salud.unm.edu', 'phone': '505-272-2610', 'title': 'Dr. Nicholas Lam', 'organization': 'University of New Mexico'}, 'certainAgreement': {'piSponsorEmployee': True, 'restrictiveAgreement': False}}, 'adverseEventsModule': {'timeFrame': 'Immediately after completion of training and assigned tasks', 'eventGroups': [{'id': 'EG000', 'title': 'STAR Strategy', 'description': 'Introductory training by video depicting 4 sequential maneuvers for reacquisition of needle image in ultrasound: see, tilt, align, rotate.', 'otherNumAtRisk': 18, 'otherNumAffected': 0, 'seriousNumAtRisk': 18, 'seriousNumAffected': 0}, {'id': 'EG001', 'title': 'ART Strategy', 'description': 'Introductory training with a video depicting 3 probe position aspects for reacquisition of needle image by ultrasound: alignment, rotation, tilt.', 'otherNumAtRisk': 17, 'otherNumAffected': 0, 'seriousNumAtRisk': 17, 'seriousNumAffected': 0}], 'frequencyThreshold': '0'}, 'outcomeMeasuresModule': {'outcomeMeasures': [{'type': 'PRIMARY', 'title': 'Task Completion Time', 'denoms': [{'units': 'Participants', 'counts': [{'value': '18', 'groupId': 'OG000'}, {'value': '17', 'groupId': 'OG001'}]}], 'groups': [{'id': 'OG000', 'title': 'STAR Strategy', 'description': 'Introductory training by video depicting 4 sequential maneuvers for reacquisition of needle image in ultrasound: see, tilt, align, rotate.'}, {'id': 'OG001', 'title': 'ART Strategy', 'description': 'Introductory training with a video depicting 3 probe position aspects for reacquisition of needle image by ultrasound: alignment, rotation, tilt.'}], 'classes': [{'categories': [{'measurements': [{'value': '87', 'groupId': 'OG000', 'lowerLimit': '47.8', 'upperLimit': '116.1'}, {'value': '343', 'groupId': 'OG001', 'lowerLimit': '214', 'upperLimit': '600'}]}]}], 'analyses': [{'pValue': '<0.001', 'groupIds': ['OG000', 'OG001'], 'ciNumSides': 'TWO_SIDED', 'statisticalMethod': 'Repeated-measures MANOVA', 'nonInferiorityType': 'SUPERIORITY_OR_OTHER', 'statisticalComment': 'The reported p value is for the effect of group assignment across three iterations of the assigned task.', 'testedNonInferiority': False}], 'paramType': 'MEDIAN', 'timeFrame': 'Immediately after training', 'description': 'Median time taken to complete 3 iterations of the assigned task, across participants within a study arm', 'unitOfMeasure': 'seconds', 'dispersionType': 'Inter-Quartile Range', 'reportingStatus': 'POSTED'}, {'type': 'SECONDARY', 'title': 'Needle-not-seen Time', 'denoms': [{'units': 'Participants', 'counts': [{'value': '18', 'groupId': 'OG000'}, {'value': '17', 'groupId': 'OG001'}]}], 'groups': [{'id': 'OG000', 'title': 'STAR Strategy', 'description': 'Introductory training by video depicting 4 sequential maneuvers for reacquisition of needle image in ultrasound: see, tilt, align, rotate.'}, {'id': 'OG001', 'title': 'ART Strategy', 'description': 'Introductory training with a video depicting 3 probe position aspects for reacquisition of needle image by ultrasound: alignment, rotation, tilt.'}], 'classes': [{'categories': [{'measurements': [{'value': '42.8', 'groupId': 'OG000', 'lowerLimit': '32.3', 'upperLimit': '68.9'}, {'value': '68.7', 'groupId': 'OG001', 'lowerLimit': '64.6', 'upperLimit': '75.1'}]}]}], 'analyses': [{'pValue': '0.004', 'groupIds': ['OG000', 'OG001'], 'ciNumSides': 'TWO_SIDED', 'statisticalMethod': 'Repeated-measures MANOVA', 'nonInferiorityType': 'SUPERIORITY_OR_OTHER', 'statisticalComment': 'The p value is for the effect of group assignment across three iterations of the assigned task.', 'testedNonInferiority': False}], 'paramType': 'MEDIAN', 'timeFrame': 'During attempt', 'description': 'Median percentage of attempt time on 3 iterations in which the needle is not adequately visualized, across participants within a study arm', 'unitOfMeasure': 'percentage of attempt time', 'dispersionType': 'Inter-Quartile Range', 'reportingStatus': 'POSTED'}, {'type': 'SECONDARY', 'title': 'Performer Fatigue', 'denoms': [{'units': 'Participants', 'counts': [{'value': '18', 'groupId': 'OG000'}, {'value': '17', 'groupId': 'OG001'}]}], 'groups': [{'id': 'OG000', 'title': 'STAR Strategy', 'description': 'Introductory training by video depicting 4 sequential maneuvers for reacquisition of needle image in ultrasound: see, tilt, align, rotate.'}, {'id': 'OG001', 'title': 'ART Strategy', 'description': 'Introductory training with a video depicting 3 probe position aspects for reacquisition of needle image by ultrasound: alignment, rotation, tilt.'}], 'classes': [{'categories': [{'measurements': [{'value': '1', 'groupId': 'OG000', 'lowerLimit': '1', 'upperLimit': '2.5'}, {'value': '4.5', 'groupId': 'OG001', 'lowerLimit': '1', 'upperLimit': '9'}]}]}], 'analyses': [{'pValue': '0.038', 'groupIds': ['OG000', 'OG001'], 'ciNumSides': 'TWO_SIDED', 'statisticalMethod': 'Wilcoxon (Mann-Whitney)', 'nonInferiorityType': 'SUPERIORITY_OR_OTHER', 'testedNonInferiority': False}], 'paramType': 'MEDIAN', 'timeFrame': 'During task', 'description': 'Self-reported trainee fatigue on a numerical rating scale (1= least fatigued; 10=most fatigued); lower scores indicate less fatigue', 'unitOfMeasure': 'units on a scale', 'dispersionType': 'Inter-Quartile Range', 'reportingStatus': 'POSTED'}, {'type': 'POST_HOC', 'title': 'Inability to Complete Assigned Task at All in Three Attempts', 'denoms': [{'units': 'Participants', 'counts': [{'value': '18', 'groupId': 'OG000'}, {'value': '17', 'groupId': 'OG001'}]}], 'groups': [{'id': 'OG000', 'title': 'STAR Strategy', 'description': 'Introductory training by video depicting 4 sequential maneuvers for reacquisition of needle image in ultrasound: see, tilt, align, rotate.'}, {'id': 'OG001', 'title': 'ART Strategy', 'description': 'Introductory training with a video depicting 3 probe position aspects for reacquisition of needle image by ultrasound: alignment, rotation, tilt.'}], 'classes': [{'categories': [{'measurements': [{'value': '0', 'groupId': 'OG000'}, {'value': '7', 'groupId': 'OG001'}]}]}], 'analyses': [{'pValue': '0.003', 'groupIds': ['OG000', 'OG001'], 'ciNumSides': 'TWO_SIDED', 'statisticalMethod': 'Fisher Exact', 'nonInferiorityType': 'SUPERIORITY_OR_OTHER', 'testedNonInferiority': False}], 'paramType': 'NUMBER', 'timeFrame': 'Immediately after training', 'description': 'Some participants found the task too difficult to complete.', 'unitOfMeasure': 'participants', 'reportingStatus': 'POSTED'}]}, 'participantFlowModule': {'groups': [{'id': 'FG000', 'title': 'STAR Strategy', 'description': 'Introductory training by video depicting 4 sequential maneuvers for reacquisition of needle image in ultrasound: see, tilt, align, rotate.'}, {'id': 'FG001', 'title': 'ART Strategy', 'description': 'Introductory training with a video depicting 3 probe position aspects for reacquisition of needle image by ultrasound: alignment, rotation, tilt.'}], 'periods': [{'title': 'Overall Study', 'milestones': [{'type': 'STARTED', 'achievements': [{'groupId': 'FG000', 'numSubjects': '18'}, {'groupId': 'FG001', 'numSubjects': '17'}]}, {'type': 'COMPLETED', 'achievements': [{'groupId': 'FG000', 'numSubjects': '18'}, {'groupId': 'FG001', 'numSubjects': '17'}]}, {'type': 'NOT COMPLETED', 'achievements': [{'groupId': 'FG000', 'numSubjects': '0'}, {'groupId': 'FG001', 'numSubjects': '0'}]}]}]}, 'baselineCharacteristicsModule': {'denoms': [{'units': 'Participants', 'counts': [{'value': '18', 'groupId': 'BG000'}, {'value': '17', 'groupId': 'BG001'}, {'value': '35', 'groupId': 'BG002'}]}], 'groups': [{'id': 'BG000', 'title': 'STAR Strategy', 'description': 'Introductory training by video depicting 4 sequential maneuvers for reacquisition of needle image in ultrasound: see, tilt, align, rotate.'}, {'id': 'BG001', 'title': 'ART Strategy', 'description': 'Introductory training with a video depicting 3 probe position aspects for reacquisition of needle image by ultrasound: alignment, rotation, tilt.'}, {'id': 'BG002', 'title': 'Total', 'description': 'Total of all reporting groups'}], 'measures': [{'title': 'Age, Continuous', 'classes': [{'categories': [{'measurements': [{'value': '21', 'groupId': 'BG000', 'lowerLimit': '19', 'upperLimit': '23.25'}, {'value': '21', 'groupId': 'BG001', 'lowerLimit': '19', 'upperLimit': '23.5'}, {'value': '21', 'groupId': 'BG002', 'lowerLimit': '19', 'upperLimit': '23'}]}]}], 'paramType': 'MEDIAN', 'unitOfMeasure': 'years', 'dispersionType': 'INTER_QUARTILE_RANGE'}, {'title': 'Gender', 'classes': [{'categories': [{'title': 'Female', 'measurements': [{'value': '7', 'groupId': 'BG000'}, {'value': '12', 'groupId': 'BG001'}, {'value': '19', 'groupId': 'BG002'}]}, {'title': 'Male', 'measurements': [{'value': '11', 'groupId': 'BG000'}, {'value': '5', 'groupId': 'BG001'}, {'value': '16', 'groupId': 'BG002'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'unitOfMeasure': 'Participants'}, {'title': 'Plays video games', 'classes': [{'categories': [{'measurements': [{'value': '7', 'groupId': 'BG000'}, {'value': '8', 'groupId': 'BG001'}, {'value': '15', 'groupId': 'BG002'}]}]}], 'paramType': 'NUMBER', 'unitOfMeasure': 'participants'}]}}, 'protocolSection': {'designModule': {'phases': ['NA'], 'studyType': 'INTERVENTIONAL', 'designInfo': {'allocation': 'RANDOMIZED', 'maskingInfo': {'masking': 'DOUBLE', 'whoMasked': ['PARTICIPANT', 'OUTCOMES_ASSESSOR']}, 'primaryPurpose': 'HEALTH_SERVICES_RESEARCH', 'interventionModel': 'PARALLEL'}, 'enrollmentInfo': {'type': 'ACTUAL', 'count': 35}}, 'statusModule': {'overallStatus': 'COMPLETED', 'startDateStruct': {'date': '2012-10'}, 'expandedAccessInfo': {'hasExpandedAccess': False}, 'statusVerifiedDate': '2016-12', 'completionDateStruct': {'date': '2013-12', 'type': 'ACTUAL'}, 'lastUpdateSubmitDate': '2016-12-20', 'studyFirstSubmitDate': '2013-12-18', 'resultsFirstSubmitDate': '2016-10-25', 'studyFirstSubmitQcDate': '2014-01-09', 'lastUpdatePostDateStruct': {'date': '2017-02-13', 'type': 'ACTUAL'}, 'resultsFirstSubmitQcDate': '2016-12-20', 'studyFirstPostDateStruct': {'date': '2014-01-10', 'type': 'ESTIMATED'}, 'resultsFirstPostDateStruct': {'date': '2017-02-13', 'type': 'ACTUAL'}, 'primaryCompletionDateStruct': {'date': '2013-12', 'type': 'ACTUAL'}}, 'outcomesModule': {'primaryOutcomes': [{'measure': 'Task Completion Time', 'timeFrame': 'Immediately after training', 'description': 'Median time taken to complete 3 iterations of the assigned task, across participants within a study arm'}], 'secondaryOutcomes': [{'measure': 'Needle-not-seen Time', 'timeFrame': 'During attempt', 'description': 'Median percentage of attempt time on 3 iterations in which the needle is not adequately visualized, across participants within a study arm'}, {'measure': 'Performer Fatigue', 'timeFrame': 'During task', 'description': 'Self-reported trainee fatigue on a numerical rating scale (1= least fatigued; 10=most fatigued); lower scores indicate less fatigue'}]}, 'oversightModule': {'oversightHasDmc': False}, 'conditionsModule': {'conditions': ['Simulator-based Training of Ultrasound-guided Regional Anesthesia']}, 'descriptionModule': {'briefSummary': 'Volunteers will watch a training video demonstrating how to place a needle in the correct position while keeping it visible. Later the volunteers will be placed in front of a set up identical to the video, and asked to demonstrate how to direct an 80 mm echogenic Pajunk needle into 3 targets in a standardized homemade phantom a total of three times.', 'detailedDescription': "After watching the training video, each volunteer will be placed in front of a set up identical to the video seen. Adjacent to this set up, a single fellowship trained regional anesthesiologist known as the assessor is situated with a screen that allows real time viewing of the ultrasound screen seen by the volunteer. The assessor is blinded to the assignment of the volunteer. Also, the assessor does not have any visualization of the volunteer. This prevents visualizing hand or body movement that may cause a bias. The same assessor is used for the whole study to provide consistent assessment of the task.\n\nThe task involves the volunteer directing an 80 mm echogenic Pajunk needle into 3 targets in a standardized homemade phantom. The targets simulate the nerve roots commonly found in the interscalene block. Thus, they are arranged diagonally to simulate the nerve root position commonly seen. Also, they are arranged on a tilt relative to the flat surface of the phantom to simulate the direction the nerve travels. This is important as the tilt of the target requires the volunteer to tilt the probe so that their incidental ultrasound wave is perpendicular to the target for the brightest reflection to occur. This phenomenon is known as anisotropy. This increases the realism of the task that cannot be imitated by commercially available phantoms.\n\nThere are 3 goals that the volunteer must fulfill in performing their task. Firstly, they must direct the needle to the 12 o'clock position of the 3 targets. Secondly, they must achieve maximal ultrasound image brightness of the 3 targets at all times. Thirdly, the entire needle must be visualized at all times.\n\nIf the needle is not in the correct position, the assessor will verbally inform the volunteer to redirect it to the correct position. If the target images are not at their brightest, the assessor will verbally inform the volunteer not to manipulate the needle towards the target until the targets are at their brightest. Clinically, this functions to prevent the needle being inserted inside the nerve as the targets are not clearly seen. Thirdly, if the needle is visualized entirely, the volunteer will be told to stop manipulating the needle towards the target until the needle is fully visualized by manipulating the probe. A timer records the cumulative time the needle is not in full visualization. Clinically, this functions to prevent the needle being inserted into a nerve or structure that it should not.\n\nAfter all 3 targets have been completed, the volunteer repeats the task a total of 3 times."}, 'eligibilityModule': {'sex': 'ALL', 'stdAges': ['ADULT'], 'maximumAge': '55 Years', 'minimumAge': '18 Years', 'healthyVolunteers': True, 'eligibilityCriteria': 'Inclusion Criteria:\n\n* Healthy volunteers\n* Right handed\n* Aged 18 to 55\n\nExclusion Criteria:\n\n* Any person who has prior knowledge about ultrasound imaging or regional anesthesia\n* Any person who has prior experience with laparoscopy or biopsy\n* Any person who has problems with depth of field or simple hand eye co-ordination task'}, 'identificationModule': {'nctId': 'NCT02032420', 'briefTitle': 'The Effects of the STAR Maneuver on UGRA Training', 'organization': {'class': 'OTHER', 'fullName': 'University of New Mexico'}, 'officialTitle': 'A Double Blinded Randomized Controlled Trial on the Effects of Four Sequential Maneuvers on Ultrasound Guided Nerve Block Performance', 'orgStudyIdInfo': {'id': 'STAR vs. ART'}}, 'armsInterventionsModule': {'armGroups': [{'type': 'EXPERIMENTAL', 'label': 'STAR', 'description': 'Introductory training by video depicting 4 sequential maneuvers for reacquisition of needle image in ultrasound: see, tilt, align, rotate.', 'interventionNames': ['Behavioral: STAR']}, {'type': 'ACTIVE_COMPARATOR', 'label': 'ART', 'description': 'Introductory training with a video depicting 3 probe position aspects for reacquisition of needle image by ultrasound: alignment, rotation, tilt.', 'interventionNames': ['Behavioral: ART']}], 'interventions': [{'name': 'STAR', 'type': 'BEHAVIORAL', 'armGroupLabels': ['STAR']}, {'name': 'ART', 'type': 'BEHAVIORAL', 'armGroupLabels': ['ART']}]}, 'contactsLocationsModule': {'locations': [{'zip': '87106', 'city': 'Albuquerque', 'state': 'New Mexico', 'country': 'United States', 'facility': 'University of New Mexico Hospital', 'geoPoint': {'lat': 35.08449, 'lon': -106.65114}}], 'overallOfficials': [{'name': 'Nicholas Lam', 'role': 'PRINCIPAL_INVESTIGATOR', 'affiliation': 'University of New Mexico'}]}, 'sponsorCollaboratorsModule': {'leadSponsor': {'name': 'University of New Mexico', 'class': 'OTHER'}, 'responsibleParty': {'type': 'PRINCIPAL_INVESTIGATOR', 'investigatorTitle': 'Research Information Specialist', 'investigatorFullName': 'Timothy R Petersen', 'investigatorAffiliation': 'University of New Mexico'}}}}