Raw JSON
{'hasResults': False, 'derivedSection': {'miscInfoModule': {'versionHolder': '2025-12-24'}}, 'protocolSection': {'designModule': {'phases': ['NA'], 'studyType': 'INTERVENTIONAL', 'designInfo': {'allocation': 'RANDOMIZED', 'maskingInfo': {'masking': 'NONE'}, 'primaryPurpose': 'BASIC_SCIENCE', 'interventionModel': 'PARALLEL', 'interventionModelDescription': '"Participants are randomly assigned to either the experimental group (Exer-Genie training) or the control group (standard training)."'}, 'enrollmentInfo': {'type': 'ACTUAL', 'count': 37}}, 'statusModule': {'overallStatus': 'COMPLETED', 'startDateStruct': {'date': '2025-04-10', 'type': 'ACTUAL'}, 'expandedAccessInfo': {'hasExpandedAccess': False}, 'statusVerifiedDate': '2025-11', 'completionDateStruct': {'date': '2025-11-01', 'type': 'ACTUAL'}, 'lastUpdateSubmitDate': '2025-11-28', 'studyFirstSubmitDate': '2025-11-28', 'studyFirstSubmitQcDate': '2025-11-28', 'lastUpdatePostDateStruct': {'date': '2025-12-10', 'type': 'ESTIMATED'}, 'studyFirstPostDateStruct': {'date': '2025-12-10', 'type': 'ESTIMATED'}, 'primaryCompletionDateStruct': {'date': '2025-06-10', 'type': 'ACTUAL'}}, 'outcomesModule': {'primaryOutcomes': [{'measure': 'Sprint Performance (30m Sprint Test)', 'timeFrame': 'Baseline (Pre-test) and immediately after the 8-week intervention (Post-test)', 'description': 'Sprint performance was evaluated using the SmartSpeed electronic timing gate system. Time was recorded in seconds for 0-10 m (acceleration), 10-30 m (transition), and full 30 m distances. Lower time indicates better performance.'}, {'measure': 'Hamstring Muscle Strength (NordBord ISO Prone)', 'timeFrame': 'Baseline (Pre-test) and immediately after the 8-week intervention (Post-test)', 'description': 'Isometric hamstring strength and impulse (force-time curve area) were assessed using the NordBord Hamstring Testing System with the ISO Prone protocol (0 degrees knee extension). Measured in Newtons (N) and N.s.'}, {'measure': 'Vertical Jump Height (Countermovement Jump)', 'timeFrame': 'Baseline (Pre-test) and immediately after the 8-week intervention (Post-test)', 'description': 'Lower-limb explosive power was assessed via the Countermovement Jump (CMJ) test using ForceDecks force platforms. Jump height was recorded in centimeters (cm).'}]}, 'oversightModule': {'oversightHasDmc': True, 'isFdaRegulatedDrug': False, 'isFdaRegulatedDevice': False}, 'conditionsModule': {'keywords': ['Resistance Training', 'Athletic Performance', 'Football'], 'conditions': ['Athletic Performance', 'Muscle Strength', 'Hamstring Muscles']}, 'descriptionModule': {'briefSummary': "This study aims to examine the effects of an eight-week Exer-Genie®-assisted speed and agility-balance-coordination (ABC drill) training program on sprint performance, hamstring muscle strength, and vertical jump ability in young female football players. A total of 37 licensed female football players competing in the Turkish Women's Second League participated in the study. Participants were randomly assigned to an experimental group (n = 20) or a control group (n = 17). The study evaluates whether this integrated training approach enhances acceleration, force production, and neuromuscular control compared to regular team training alone.", 'detailedDescription': "Study Design and Participants The study involves 37 female football players from the Pendik Güven Women's Football Team (mean age 14.4 ± 1.4 years), licensed by the Turkish Football Federation. Participants were randomly assigned to an experimental group (n = 20) or a control group (n = 17).\n\nIntervention Protocol The experimental group completed an Exer-Genie®-assisted sprint and ABC drill training program twice per week for eight weeks (total of 16 sessions). Each session was performed after a standardized warm-up and consisted of six 30-m sprint runs and technical drills. The sprints were performed with resistance applied using the 60-m Exer-Genie® device, with resistance intensity set at 10% of each athlete's body weight. The control group continued with their regular team training only.Outcome Measures 1. Sprint Performance: Assessed via 0-10 m, 10-30 m, and 30 m sprint times using the SmartSpeed electronic timing gate system. 2. Hamstring Strength: Assessed using the NordBord Hamstring Testing System. Specifically, the ISO Prone (0°) protocol was used to measure isometric hamstring strength and impulse values. 3. Vertical Jump: Assessed via the Countermovement Jump (CMJ) test using the ForceDecks system to evaluate lower-limb explosive performance.Statistical Analysis Data were analyzed using repeated-measures ANOVA to evaluate time, group, and interaction effects, with a significance level set at p \\< 0.05."}, 'eligibilityModule': {'sex': 'FEMALE', 'stdAges': ['CHILD'], 'maximumAge': '17 Years', 'minimumAge': '11 Years', 'healthyVolunteers': True, 'eligibilityCriteria': "Inclusion Criteria:\n\nFemale gender.\n\nLicensed football players competing in the Turkish Women's Second League.\n\nRegularly engaged in football training for at least two years.\n\nAged between 11 and 17 years.\n\nExclusion Criteria:\n\nHistory of recent musculoskeletal injury.\n\nAny chronic health condition that could affect athletic performance.\n\nIrregular attendance to the training sessions during the study period."}, 'identificationModule': {'nctId': 'NCT07274566', 'briefTitle': 'The Effects of an 8-Week Exer-Genie-Assisted Speed and ABC Drill Training Program on Speed, Hamstring Strength, and Vertical Jump Performance in Female Football Players', 'organization': {'class': 'OTHER', 'fullName': 'Istanbul Rumeli University'}, 'officialTitle': 'The Effects of an 8-Week Exer-Genie-Assisted Speed and ABC Drill Training Program on Speed, Hamstring Strength, and Vertical Jump Performance in Female Football Players', 'orgStudyIdInfo': {'id': 'EXERGENIE-FOOTBALL-2025'}}, 'armsInterventionsModule': {'armGroups': [{'type': 'EXPERIMENTAL', 'label': 'Experimental Group', 'description': 'Participants in this group performed an Exer-Genie®-assisted sprint and agility-balance-coordination (ABC drill) training program twice per week for eight weeks in addition to their warm-up routine.', 'interventionNames': ['Other: Exer-Genie® Training Protocol']}, {'type': 'NO_INTERVENTION', 'label': 'Control Group', 'description': 'Participants in this group continued with their regular team football training only and did not receive the Exer-Genie® resistance training.'}], 'interventions': [{'name': 'Exer-Genie® Training Protocol', 'type': 'OTHER', 'description': "The protocol consisted of six 30-m sprint runs performed with resistance applied using the 60-m Exer-Genie® device. Resistance was set at 10% of the athlete's body weight. The training was conducted twice a week for 8 weeks.", 'armGroupLabels': ['Experimental Group']}]}, 'contactsLocationsModule': {'locations': [{'city': 'Istanbul', 'country': 'Turkey (Türkiye)', 'facility': 'Istanbul Gedik University, Faculty of Sport Sciences, Indoor Sports Hall', 'geoPoint': {'lat': 41.01384, 'lon': 28.94966}}]}, 'ipdSharingStatementModule': {'infoTypes': ['STUDY_PROTOCOL', 'SAP'], 'timeFrame': 'Data will be available beginning immediately after publication of the study results.', 'ipdSharing': 'YES', 'description': '"The datasets generated and analyzed during the current study are available from the corresponding author on reasonable request."', 'accessCriteria': 'Data will be shared with researchers who provide a methodologically sound proposal. Requests should be directed to the corresponding author (Yusufcan Keskin) via email.'}, 'sponsorCollaboratorsModule': {'leadSponsor': {'name': 'Istanbul Rumeli University', 'class': 'OTHER'}, 'responsibleParty': {'type': 'PRINCIPAL_INVESTIGATOR', 'investigatorTitle': 'PhD Student / Research Assistant', 'investigatorFullName': 'Yusufcan Keskin', 'investigatorAffiliation': 'Istanbul Gedik University'}}}}